Медицинская библиотека · Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2003

[Multifocal steady-state pattern-reversal electroretinography in glaucoma patients].

Lindenberg Th, Horn F K, Korth M

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: This study was designed to answer the question of whether multifocal steady-state pattern-reversal electroretinography (ERG) is capable of detecting glaucomatous visual field defects.

METHOD: Sixteen patients (28 eyes) and ten normal subjects (20 eyes) were examined. Multifocal pattern ERGs were recorded with the RETIscan system and DTL electrodes. We stimulated with a steady-state checkerboard pattern reversal (three reversals during 171 ms sweep length, congruent with 17.5 reversals/s). The multifocal pattern ERG amplitudes were evaluated using discrete Fourier transformation (DFT) across three reversals. In cases of advanced glaucoma, the DFT-calculated amplitudes were combined in hemispheres and checked for correlations with corresponding visual field defects. In all binocularly examined persons, side comparisons ("worse" eye vs "better" eye), and interindividual comparisons (glaucoma vs normal) were carried out.

RESULTS

In interindividual comparisons and interocular side comparisons, significant amplitude reductions of the "worse" eyes were seen in the foveal records. No topographical correlation between multifocal pattern ERG amplitudes and visual field defects could be found.

CONCLUSIONS

In glaucomatous visual field defects, multifocal steady-state pattern-reversal ERG using the present stimulation was significantly reduced in its foveal records but seems to be incapable of detecting them topographically.

Для цитирования: Lindenberg Th, Horn F K, Korth M. [Multifocal steady-state pattern-reversal electroretinography in glaucoma patients].. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2003. DOI: 10.1007/s00347-002-0759-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.