MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.84.9.1008

Медицинская библиотека · The British journal of ophthalmology · 2000

Altitudinal visual field asymmetry is coupled with altered retinal circulation in patients with normal pressure glaucoma.

Arend O, Remky A, Cantor L B, Harris A

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

AIM: To compare the effect of altitudinal asymmetric glaucomatous damage on retinal microcirculation in patients with normal pressure glaucoma (NPG).

METHODS

In a prospective cross sectional study patients with NPG (washed out for antiglaucomatous therapy) and altitudinal asymmetric perimetric findings between the superior and inferior hemisphere (Humphrey 24-2) (n=18) were included and compared with 20 NPG patients with symmetrical field defects and 18 healthy subjects. Fluorescein angiograms were performed using a scanning laser ophthalmoscope. Using digital image analysis, arteriovenous passage time (AVP) and vessel diameters were assessed for comparison of corresponding affected and less affected temporal arcades.

RESULTS

Both affected and less affected hemispheres showed significantly prolonged AVP times (p<0.001) when compared with healthy subject data. In hemispheres with more severe glaucomatous field loss the AVP times were significantly (p=0.04) prolonged compared with the less affected hemisphere (AVP affected 3.1 (SD 7) seconds v AVP less affected 2.61 (1.4) seconds). There was no asymmetry effect on arterial and venous diameter measurements.

CONCLUSION

Altitudinal visual field defects are linked together with circulatory deficits of the retinal tissue. The attenuated circulation seems to be a considerable factor in the natural course of glaucomatous optic neuropathy.

Для цитирования: Arend O, Remky A, Cantor L B, Harris A. Altitudinal visual field asymmetry is coupled with altered retinal circulation in patients with normal pressure glaucoma.. The British journal of ophthalmology. 2000. DOI: 10.1136/bjo.84.9.1008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.