MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-013-2958-z

Медицинская библиотека · European radiology · 2013

Computed diffusion-weighted imaging using 3-T magnetic resonance imaging for prostate cancer diagnosis.

Ueno Yoshiko, Takahashi Satoru, Kitajima Kazuhiro, Kimura Tokunori, Aoki Ikuo, Kawakami Fumi, Miyake Hideaki, Ohno Yoshiharu, Sugimura Kazuro

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the efficacy of computed diffusion-weighted images (cDWIs) of b = 2000 s/mm(2) (cDWI2000) generated from DWIs of b = 0 and 1000 for prostate cancer (PCa) diagnosis in comparison with that of measured original DWIs of b = 1000 (mDWI1000) and b = 2000(mDWI2000) using 3-T MRI.

METHODS

Eighty patients who underwent a preoperative MRI examination, including T2WI and DWI (b = 0, 1000, 2000 s/mm(2)), were enrolled in this study. Four combinations of images, protocol A (T2WI alone), B (T2WI + mDWI1000), C (T2WI + mDWI2000) and D (T2WI + cDWI2000), were assessed for their diagnostic capability. Areas under the receiver operating characteristic curve (Az) and diagnostic performance were evaluated, as well as contrast ratios (CR) between cancerous and non-cancerous lesions for each DWI.

RESULTS

The highest CR was obtained with cDWI2000 (0.29 ± 0.16). Sensitivity, specificity, accuracy, and Az of the protocols were: A: 66.3 %, 59.4 %, 63.0 %, 0.67; B: 82.6 %, 62.0 %, 72.5 %, 0.80; C: 84.1 %, 66.5 %, 75.5 %, 0.86; D: 83.2 %, 70.0 %, 76.6 %, and 0.84, respectively The specificities and accuracies of protocol C and D were significantly higher than those of protocol B (P < 0.05).

CONCLUSION

cDWI2000 appears to be more effective than mDWI1000, and at least as effective as mDWI2000 for PCa diagnosis.

Для цитирования: Ueno Yoshiko, Takahashi Satoru, Kitajima Kazuhiro, Kimura Tokunori, Aoki Ikuo, Kawakami Fumi, Miyake Hideaki, Ohno Yoshiharu, Sugimura Kazuro. Computed diffusion-weighted imaging using 3-T magnetic resonance imaging for prostate cancer diagnosis.. European radiology. 2013. DOI: 10.1007/s00330-013-2958-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.