MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10147-010-0129-7

Медицинская библиотека · International journal of clinical oncology · 2010

Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer.

Takayama Kenji, Mizowaki Takashi, Negoro Yoshiharu, Norihisa Yoshiki, Hiraoka Masahiro

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUNDS: Prostate motion and rectal sparing are important treatment strategy issues in external-beam radiotherapy for localized prostate cancer. To address these issues, we prospectively investigated the feasibility of using a double-balloon rectal catheter.

METHODS

The rectal catheter has inner and outer balloons that wedge the anus between them. Computed tomography (CT) examinations with and without the catheter were conducted in seven patients with localized prostate cancer treated by external-beam radiotherapy. The rectal wall sparing effect was evaluated using virtual three-dimensional conformal radiotherapy plans in each arm. To evaluate interfractional prostate motion, each patient underwent a series of four CT examinations consisting of a planning CT followed by three additional series of CT with and without a catheter during the course of radiotherapy.

RESULTS

Virtual plans demonstrated the reduction of the dose to the rectum by expanding the posterior wall to lie outside the high- to intermediate-dose area when a catheter was applied. Interfractional prostate motion in the anteroposterior direction was effectively reduced by catheter usage; the mean ± standard deviation (SD) of the displacement was 1.3 ± 0.9 mm with a catheter as compared to 2.8 ± 1.8 mm without a catheter (P = 0.014), and the maximum displacement was successfully suppressed to 3 mm with a catheter compared to 6 mm without a catheter. Systematic and random components were also reduced with the catheter.

CONCLUSION

These results suggest the feasibility and clinical applicability of the double-balloon rectal catheter.

Для цитирования: Takayama Kenji, Mizowaki Takashi, Negoro Yoshiharu, Norihisa Yoshiki, Hiraoka Masahiro. Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer.. International journal of clinical oncology. 2010. DOI: 10.1007/s10147-010-0129-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.