Polymicrobial keratitis after a collagen cross-linking procedure with postoperative use of a contact lens: a case report.

Zamora Katherine V, Males John J

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: : To report a case of polymicrobial keratitis caused by Streptococcus salivarius, Streptococcus oralis, and coagulase-negative Staphylococcus sp. in a patient who underwent collagen cross-linking for keratoconus.

METHOD: : Case report.

RESULT: : A 32-year-old male presented with a 1-day history of a painful red eye, occurring 3 days after he had undergone a collagen cross-linking with riboflavin and UV-A on his left eye for keratoconus. He admitted to removing his bandage contact lens and cleaning it in his mouth before reapplying it in his eye. On presentation, a severe keratitis with an 8-mm epithelial defect and 360-degree ring infiltrate was found. Culture results from his contact lens were positive for S. salivarius and S. oralis, and coagulase-negative Staphylococcus sp. were grown from his corneal scrapings.

CONCLUSIONS

: Collagen cross-linking is a promising procedure for the treatment of progressive keratoconus with minimal reported side effects. However, the possibility of a secondary infection after the procedure exists because the patient is subjected to epithelial debridement and the application of a soft contact lens. The role of the UV light on the immune mechanisms of the cornea and its effect on corneal wound healing warrant further investigation.

Для цитирования: Zamora Katherine V, Males John J. Polymicrobial keratitis after a collagen cross-linking procedure with postoperative use of a contact lens: a case report.. Cornea. 2009. DOI: 10.1097/ico.0b013e31818d381a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.