MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181606070

Медицинская библиотека · Cornea · 2008

Novel technique of corneal biopsy by using a femtosecond laser in infectious ulcers.

Kim Jin-Hyoung, Yum Jung-Hoon, Lee Doh, Oh Sae-Hoon

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe femtosecond laser-assisted corneal biopsy and its use in assessing the causative organisms in 2 cases of infectious corneal ulcers.

METHODS

A 27-year-old man and a 65-year-old woman, both of whom showed uncertain symptoms, repeated negative test results for infectious organisms, and after no improvement despite empirical therapy, underwent diagnostic corneal biopsy by using a femtosecond laser. A corneal flap depth of 200 microm and a diameter of 3 mm were obtained from each patient.

RESULTS

The biopsy specimen from the male patient showed pseudohyphae, which led to a diagnosis of candidal keratitis. The biopsy specimen from the female patient showed positive Gram stain and no evidence of fungal ulcers and yielded a culture of Streptococcus viridans. No complications occurred during either procedure.

CONCLUSIONS

Femtosecond laser-assisted corneal biopsy enabled identification of the infectious pathogen in both patients. This technique is easy, safe, and rapid, and it yields a biopsy specimen with a uniform depth and precise size. Femtosecond laser-assisted corneal biopsy can be used as an accurate diagnostic method in uncertain cases of corneal ulcers.

Для цитирования: Kim Jin-Hyoung, Yum Jung-Hoon, Lee Doh, Oh Sae-Hoon. Novel technique of corneal biopsy by using a femtosecond laser in infectious ulcers.. Cornea. 2008. DOI: 10.1097/ico.0b013e3181606070.