MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12967-022-03289-8

Медицинская библиотека · Journal of translational medicine · 2022

Physiological assessment of orthostatic intolerance in chronic fatigue syndrome.

Natelson Benjamin H, Lin Jin-Mann S, Blate Michelle, Khan Sarah, Chen Yang, Unger Elizabeth R

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Orthostatic intolerance-OI is common in Myalgic Encephalomyelitis/Chronic Fatigue Syndrome-ME/CFS. We used a 10-min passive vertical lean test as orthostatic challenge-OC and measured changes in vitals and end tidal CO2 (eTCO2). An abnormal physiologic response to OC was identified in 60% of the 63 patients evaluated from one to three times over several years. Hypocapnia, either resting or induced by OC, was the most frequent abnormality, followed by postural orthostatic tachycardia.

OBJECTIVE

Evaluate the physiologic response of patients with ME/CFS to a standardized OC.

DESIGN

Respiratory and heart rate, blood pressure and eTCO2 were recorded twice at the end of 10-min supine rest and then every minute during the 10-min lean. Hypocapnia was eTCO2 ≤ 32 mmHg. Orthostatic tachycardia was heart rate increase ≥ 30 beats per minute compared with resting or ≥ 120 BPM. Orthostatic hypotension was decreased systolic pressure ≥ 20 mmHg from baseline. Tachypnea was respiratory rate of  ≥ 20 breaths per minute-either supine or leaning. Questionnaire data on symptom severity, quality of life and mood were collected at visit #2.

PATIENTS: 63 consecutive patients fulfilling the 1994 case definition for CFS underwent lean testing at first visit and then annually at visit 2 (n = 48) and 3 (n = 29).

MEASURES: Supine hypocapnia; orthostatic tachycardia, hypocapnia or hypotension.

RESULTS

The majority of ME/CFS patients (60.3%, 38/63) had an abnormality detected during a lean test at any visit (51%, 50% and 45% at visits 1, 2 and 3, respectively). Hypocapnia at rest or induced by OC was more common and more likely to persist than postural orthostatic tachycardia. Anxiety scores did not differ between those with and without hypocapnia.

CONCLUSIONS

The 10-min lean test is useful in evaluation of OI in patients with ME/CFS. The most frequent abnormality, hypocapnia, would be missed without capnography.

Для цитирования: Natelson Benjamin H, Lin Jin-Mann S, Blate Michelle, Khan Sarah, Chen Yang, Unger Elizabeth R. Physiological assessment of orthostatic intolerance in chronic fatigue syndrome.. Journal of translational medicine. 2022. DOI: 10.1186/s12967-022-03289-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.