Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals.

Huang Baogen, Wang Feng, Li Jing, Sun Suping, Lv Huiying, Lu Lu, Shi Quan, Ding Chenchen, Mao Yiping

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the disinfection efficacy of a third-generation gallium nitride (GaN)-based deep ultraviolet (UVC) LED disinfection cabinet on often-touch surfaces of small advanced electronic devices in hospital clinical environments, and to provide evidence for its application in hospital infection control.

METHODS

A total of 329 device surfaces from 10 randomly selected departments were sampled: 66 computer mice, 151 mobile phones, 53 Personal Digital Assistants (PDAs), 29 electronic glucometers, and 30 electronic sphygmomanometers. Pre-disinfection bacterial contamination levels were assessed. The UVC-LED cabinet was used for disinfection (10-min cycle, 24 mJ/cm2 dose), and a natural bacteria eradication test was conducted.

RESULTS

A total of 658 sampling points (329 pre- and post-disinfection) were monitored. Before disinfection, 57.1% of device surfaces showed microbial contamination, with mice and cleaning staff's mobile phones exhibiting relatively severe bacterial contamination. After disinfection, 97.9% of device surfaces showed bacterial colony counts reduced to 0 CFU, with an average natural bacteria eradication rate of 99.9% (range ≥90%).

CONCLUSION

High-frequency use of small advanced electronic devices by healthcare workers poses hospital infection risks. Deep LED Ultraviolet-C disinfection effectively reduces microbial load on surfaces of devices incompatible with chemical disinfectants or heat. It is recommended as a routine disinfection measure for hospital infection control. This study demonstrates high efficacy under controlled conditions; however, real-world effectiveness may be influenced by factors such as device positioning and surface shadows.

Для цитирования: Huang Baogen, Wang Feng, Li Jing, Sun Suping, Lv Huiying, Lu Lu, Shi Quan, Ding Chenchen, Mao Yiping. Experimental study on deep ultraviolet-C LED disinfection device for often-touch surfaces of advanced medical equipment in hospitals.. Frontiers in public health. 2026. DOI: 10.3389/fpubh.2025.1700856.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.