DOI 10.1016/j.clinph.2015.03.024

Медицинская библиотека · Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2015

Ultrasound for assessment of diaphragm in ALS.

Pinto Susana, Alves Pedro, Pimentel Bernardo, Swash Michael, de Carvalho Mamede

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the correlation between diaphragm thickness assessed by ultrasound (US) with respiratory function tests and the diaphragm motor responses, in patients with amyotrophic lateral sclerosis (ALS).

METHODS

42 consecutive ALS patients were studied (11 with bulbar-onset), excluding patients with marked orofacial paresis. Investigation included: revised ALS functional rating scale (ALSFRS-R), forced vital capacity (FVC), maximal voluntary ventilation (MVV), maximal inspiratory (MIP) and expiratory (MEP) pressures, nasal inspiratory pressure during sniff (SNIP); peak-to-peak amplitude of the diaphragmatic motor response to phrenic nerve stimulation (Diaphragm-CMAP), diaphragmatic thickness measured by ultrasound during maximal inspiration and during maximal expiration. Patients were analysed in bulbar or spinal subgroups. Correlations and multiple linear regression models were studied.

RESULTS

The mean age at disease onset was 58.4 ± 11.1 years and with a mean disease duration of 17.8 ± 13.6 months. Ultrasound studies of diaphragm thickness in full inspiration correlated with diaphragm CMAP in the whole population and in spinal-onset patients; and were similar in the two groups. Multiple linear modelling showed that FVC, SNIP and MVV were dependent on the change of thickness (p=0.001, 0.001 and 0.020, respectively) and that MIP and MEP were related to diaphragm CMAP p=0.003 and p=0.025, respectively).

CONCLUSION

Diaphragm thickness correlates with Diaphragm-CMAP, except in bulbar-onset patients. Respiratory tests are dependent on both diaphragm thickness and Diaphragm-CMAP.

SIGNIFICANCE: US thickness of the diaphragm correlates with the number of functional motor units as assessed by the phrenic nerve motor amplitude.

Для цитирования: Pinto Susana, Alves Pedro, Pimentel Bernardo, Swash Michael, de Carvalho Mamede. Ultrasound for assessment of diaphragm in ALS.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2015. DOI: 10.1016/j.clinph.2015.03.024.