Effects of pacing rates on global and regional myocardial blood flow.

Ten Cate Tim J F, Knaapen Paul, Lammertsma Adriaan A, De Cock Carel C, Van Hemel Norbert M, Verzijlbergen J Fred

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Information is scarce on the effects of right ventricular apical (RVA) pacing on regional and global myocardial blood flow (MBF). The purpose of this study was to assess the relationship between pacing rate and both regional and global MBF.

METHODS

Four patients with exclusive atrial pacing and six patients with exclusive RVA pacing underwent three consecutive H(2) (15)O positron emission tomography scans at 60, 90, and 130 pulses per minute (ppm). For each pacing rate, regional and global MBF was determined. In all patients, the left ventricular (LV) function was normal.

RESULTS

By varying the atrial pacing rate from 60 to 130 ppm, the mean global MBF increased from 0.94 to 1.40 mL/g/min, whereas the mean septal to lateral MBF ratio decreased from 1.09 to 0.83. In ventricular-paced patients at corresponding rates, the mean global MBF also increased from 1.07 to 1.52 mL/g/min but here the mean septal to lateral MBF ratio increased from 0.83 to 1.0.

CONCLUSIONS

During both acute atrial and RVA pacing, regional and global MBF increases with higher pacing rates. However, the septal to lateral MBF ratio decreases with atrial pacing and increases with RVA pacing in patients with normal LV function. In RVA pacing, these different rate-dependent effects on regional MBF can be considered as a favorable factor that helps to understand why in some long-term paced patients, LV function is preserved.

Для цитирования: Ten Cate Tim J F, Knaapen Paul, Lammertsma Adriaan A, De Cock Carel C, Van Hemel Norbert M, Verzijlbergen J Fred. Effects of pacing rates on global and regional myocardial blood flow.. Pacing and clinical electrophysiology : PACE. 2011. DOI: 10.1111/j.1540-8159.2010.03013.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.