Validation of rapid automated tissue synchronization imaging for the assessment of cardiac dyssynchrony in sinus and non-sinus rhythm.

Kearney Leighton G, Wai Bryan, Ord Michelle, Burrell Louise M, O'Donnell David, Srivastava Piyush M

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: Cardiac resynchronization therapy is showing benefits for an increasing number of indications but fails to predict response in up to 20-30% of subjects. Echocardiographically assessed dyssynchrony has been proposed as a potential stratifier but current methods are time-consuming and suffer poor reproducibility, thus limiting their clinical utility. This study compared the accuracy, time efficiency, and reproducibility of automated tissue synchronization imaging (Auto TSI) vs. established manual tissue velocity imaging (TVI) techniques for the assessment of intra-ventricular dyssynchrony in sinus and non-sinus rhythm.

METHODS AND

RESULTS

Fifty consecutive stable systolic heart failure patients on optimal guideline-based medical therapy underwent intra-ventricular dyssynchrony assessment [time to peak velocity (Ts), septal to lateral delay (SLD), and dyssynchrony index (DI)] with TVI and Auto TSI techniques, enabling the assessment of agreement, time efficiency, and reproducibility. Statistical analyses included Pearson's correlation, Bland-Altman's statistics, and coefficient of reproducibility. There was excellent agreement between Auto TSI and TVI for the measurement of Ts [r=0.92, P<0.001, limits of agreement (LOA): -27.3 to 56.5 ms], SLD (r=0.94, P<0.001, LOA: -41 to 49 ms), and DI (r=0.89, P<0.001, LOA: -12.2 to 12.6 ms) which persisted irrespective of cardiac rhythm [Ts: sinus (n=32) r=0.93, P<0.001; non-sinus (n=18) r=0.91, P<0.001]. Automated TSI was more time efficient (3±1 vs. 14±2 min, P<0.001) and demonstrated superior reproducibility: intra-observer (5.5 vs. 9.6%) and inter-observer variability (9.5 vs. 13.4%).

CONCLUSION

Automated TSI enables rapid, reproducible intra-ventricular dyssynchrony assessment and overcomes some of the limitations of conventional techniques in sinus and non-sinus rhythm.

Для цитирования: Kearney Leighton G, Wai Bryan, Ord Michelle, Burrell Louise M, O'Donnell David, Srivastava Piyush M. Validation of rapid automated tissue synchronization imaging for the assessment of cardiac dyssynchrony in sinus and non-sinus rhythm.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2011. DOI: 10.1093/europace/euq442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.