MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2010.51.6.832

Медицинская библиотека · Yonsei medical journal · 2010

Long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction.

Kim Won Ho, Joung Boyoung, Shim Jaemin, Park Jong Sung, Hwang Eui-Seock, Pak Hui-Nam, Kim Sungsoon, Lee Moonhyoung

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction.

MATERIALS AND

METHODS

Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared.

RESULTS

The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02].

CONCLUSION

In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction.

Для цитирования: Kim Won Ho, Joung Boyoung, Shim Jaemin, Park Jong Sung, Hwang Eui-Seock, Pak Hui-Nam, Kim Sungsoon, Lee Moonhyoung. Long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction.. Yonsei medical journal. 2010. DOI: 10.3349/ymj.2010.51.6.832.