Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2010
Long-term patient acceptance of and satisfaction with implanted device remote monitoring.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ricci Renato Pietro, Morichelli Loredana, Quarta Laura, Sassi Anna, Porfili Antonio, Laudadio Maria Teresa, Gargaro Alessio, Santini Massimo
Аннотация
AIMS: To evaluate patients' acceptance and satisfaction of the Home Monitoring (HM) remote control system after 1 year of follow-up by a self-made questionnaire (HM Acceptance and Satisfaction Questionnaire, HoMASQ) specifically designed for this purpose.
METHODS AND RESULTS: The HoMASQ contains 12 items designed to investigate five different aspects strictly connected to patient's acceptance and satisfaction of remote monitoring: (i) relationship with their healthcare provider, (ii) easy of use of HM technology, (iii) related psychological aspects, (iv) implications on general health, and (v) overall satisfaction. Each item was rated on a five-point scale: from 0 to 4 with favourable responses score > or =2. The theoretical maximum total score (the highest detected acceptance and satisfaction level) was 48. The HoMASQ was given to 119 patients followed by HM during the 1-year follow-up visit. Ninety-nine percent of all the administered questionnaire items were answered. The mean total score was 40.8 +/- 5.4 with a mean percentage of favourable answers of 96.3 +/- 18.8% (CI 95.2 - 97.2%). The mean scores for each of the five areas of the HoMASQ were: 3.0 +/- 0.9 for relationship, 3.4 +/- 0.6 for easy of use, 3.4 +/- 0.9 for psychological aspects, and 3.4 +/- 0.8 for clinical implication and overall satisfaction. Cronbach's alpha for reliability of the HoMASQ was 0.73.
CONCLUSION: A high level of acceptance and satisfaction after 1-year remote control by HM was detected by the five-point scale HoMASQ, which showed a good internal reliability.
METHODS AND RESULTS: The HoMASQ contains 12 items designed to investigate five different aspects strictly connected to patient's acceptance and satisfaction of remote monitoring: (i) relationship with their healthcare provider, (ii) easy of use of HM technology, (iii) related psychological aspects, (iv) implications on general health, and (v) overall satisfaction. Each item was rated on a five-point scale: from 0 to 4 with favourable responses score > or =2. The theoretical maximum total score (the highest detected acceptance and satisfaction level) was 48. The HoMASQ was given to 119 patients followed by HM during the 1-year follow-up visit. Ninety-nine percent of all the administered questionnaire items were answered. The mean total score was 40.8 +/- 5.4 with a mean percentage of favourable answers of 96.3 +/- 18.8% (CI 95.2 - 97.2%). The mean scores for each of the five areas of the HoMASQ were: 3.0 +/- 0.9 for relationship, 3.4 +/- 0.6 for easy of use, 3.4 +/- 0.9 for psychological aspects, and 3.4 +/- 0.8 for clinical implication and overall satisfaction. Cronbach's alpha for reliability of the HoMASQ was 0.73.
CONCLUSION: A high level of acceptance and satisfaction after 1-year remote control by HM was detected by the five-point scale HoMASQ, which showed a good internal reliability.
Предметные рубрики MeSH
AgedAged, 80 and overArrhythmias, CardiacAtrioventricular BlockDefibrillators, ImplantableElectrocardiography, AmbulatoryFemaleFollow-Up StudiesHumansLongitudinal StudiesMaleMiddle AgedPatient Acceptance of Health CarePatient SatisfactionPhysician-Patient RelationsQuality of LifeRegression AnalysisReproducibility of ResultsSick Sinus SyndromeSurveys and QuestionnairesSyncope, Vasovagal