Right ventricular apical pacing impairs left ventricular twist as well as synchrony: acute effects of right ventricular apical pacing.

Matsuoka Ken, Nishino Masami, Kato Hiroyasu, Egami Yasuyuki, Shutta Ryu, Yamaguchi Hitoshi, Tanaka Kenjiro, Tanouchi Jun, Yamada Yoshio

Контролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study was designed to compare the rotation of the left ventricular (LV) apex and base, LV synchrony between LV apical and basal rotation, and LV twist, changing from intrinsic atrioventricular conduction to right ventricular apical (RVA) pacing.

METHODS

Thirty consecutive patients with sick sinus syndrome who had undergone DDD pacemaker implantation were studied. Changing from intrinsic atrioventricular conduction to RVA pacing, the acute effect on echocardiographic parameters, including LV rotation and twist and LV apical-basal rotation delay, was assessed.

RESULTS

During RVA pacing, values of peak rotation in the LV apex and base and LV twist were significantly lower than during intrinsic atrioventricular conduction (P=.007, P=.003, and P<.0001, respectively). Apical-basal rotation delay during RVA pacing was significantly longer than during intrinsic atrioventricular conduction (P=.02).

CONCLUSIONS

RVA pacing decreases apical and basal LV rotation and induces LV apical-basal rotation delay, resulting in impairment of LV twist.

Для цитирования: Matsuoka Ken, Nishino Masami, Kato Hiroyasu, Egami Yasuyuki, Shutta Ryu, Yamaguchi Hitoshi, Tanaka Kenjiro, Tanouchi Jun, Yamada Yoshio. Right ventricular apical pacing impairs left ventricular twist as well as synchrony: acute effects of right ventricular apical pacing.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2009. DOI: 10.1016/j.echo.2009.05.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.