Long-term reliability of AAI mode pacing in patients with sinus node dysfunction and low Wenckebach block rate.

Adachi Masamitsu, Igawa Osamu, Yano Akio, Miake Junichiro, Inoue Yoshiaki, Ogura Kazuyoshi, Kato Masaru, Iitsuka Kazuhiko, Hisatome Ichiro

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To compare the risk of atrioventricular (AV) conduction disturbance between patients with sinus node dysfunction on AAI pacing who had a low or high Wenckebach block rate (WBR).

METHODS AND

RESULTS

Patients with sinus node dysfunction and normal AV conduction those underwent an electrophysiological study were studied. The patients were classified into two groups: Group L was with the patients with a WBR of 100 to 129 per minute and Group H was with the patients with a WBR > or = 130 per minute. All patients followed up every 3-6 months after an AAI pacemaker implantation. A total of 102 patients, including 35 Group L and 67 Group H, were followed for 90 +/- 44 months. Six patients died from non-cardiac cause and five patients required a new atrial lead implantation due to lead failure during follow-up. Symptomatic bradycardia requiring a new ventricular lead implantation developed in four patients (annual incidence 0.5%). In Group L, two patients developed AV block (annual incidence 0.7%). In Group H, two patients developed bradycardic atrial fibrillation (annual incidence 0.4%). Kaplan-Meier analysis revealed no significant difference between the two groups (P = 0.2983).

CONCLUSION

These results suggest that a long-term risk of developing AV conduction disturbance is low even in patients with a WBR of 100 to 129 per minute.

Для цитирования: Adachi Masamitsu, Igawa Osamu, Yano Akio, Miake Junichiro, Inoue Yoshiaki, Ogura Kazuyoshi, Kato Masaru, Iitsuka Kazuhiko, Hisatome Ichiro. Long-term reliability of AAI mode pacing in patients with sinus node dysfunction and low Wenckebach block rate.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2008. DOI: 10.1093/europace/eum290.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.