Heart rhythm · 2007
Right ventricular pacing-induced electrophysiological remodeling in the human heart and its relationship to cardiac memory.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wecke Liliane, Rubulis Aigars, Lundahl Gunilla, Rosen Michael R, Bergfeldt Lennart
Аннотация
BACKGROUND: Right ventricular apical (RVA) pacing induces electrophysiological and structural remodeling. Cardiac memory (CM) evolves during the course of pacing and is readily apparent on electrocardiography (ECG) or vectorcardiography (VCG) when normal ventricular activation resumes.
OBJECTIVE: This study sought to assess ventricular repolarization (VR) changes during pacing and intermittent normal ventricular conduction by ECG and VCG and to determine the temporal and conformational evolution of CM.
METHODS: Twenty sick sinus patients received a dual-chamber rate-adaptive (DDD-R) pacemaker and were paced from the RVA endocardium. The pacemakers were programmed to a short AV delay to maximize ventricular preexcitation. The ECG and VCG were recorded before and 1 day after implantation, and then daily for the first week (n=6) or weekly for 5 to 8 weeks (n=14), with the pacemakers temporarily programmed to AAI (normal ventricular activation).
RESULTS: The first parameters to change were T-vector amplitude, T(area), and T(peak)-T(end) (T(p-e)), which decreased within 1 day after initiating pacing. CM became apparent between day 1 and day 3, was fully established after 1 week, and then remained stable. Signs of increased VR heterogeneity were observed as the T loop became more circular (decreased T(egenv)) and distorted (increased T(avplan)), which have previously been observed in conditions with increased risk for arrhythmias. Over weeks, VR duration was prolonged (increased QTc). In contrast, during ventricular pacing, a gradual shortening of the repolarization time was observed, suggesting a stabilizing adaptive process.
CONCLUSION: In sick sinus syndrome patients in whom ventricular pacing is indicated, switching between normal AV conduction and ventricular pacing should be minimized to avoid periods of repolarization instability.
OBJECTIVE: This study sought to assess ventricular repolarization (VR) changes during pacing and intermittent normal ventricular conduction by ECG and VCG and to determine the temporal and conformational evolution of CM.
METHODS: Twenty sick sinus patients received a dual-chamber rate-adaptive (DDD-R) pacemaker and were paced from the RVA endocardium. The pacemakers were programmed to a short AV delay to maximize ventricular preexcitation. The ECG and VCG were recorded before and 1 day after implantation, and then daily for the first week (n=6) or weekly for 5 to 8 weeks (n=14), with the pacemakers temporarily programmed to AAI (normal ventricular activation).
RESULTS: The first parameters to change were T-vector amplitude, T(area), and T(peak)-T(end) (T(p-e)), which decreased within 1 day after initiating pacing. CM became apparent between day 1 and day 3, was fully established after 1 week, and then remained stable. Signs of increased VR heterogeneity were observed as the T loop became more circular (decreased T(egenv)) and distorted (increased T(avplan)), which have previously been observed in conditions with increased risk for arrhythmias. Over weeks, VR duration was prolonged (increased QTc). In contrast, during ventricular pacing, a gradual shortening of the repolarization time was observed, suggesting a stabilizing adaptive process.
CONCLUSION: In sick sinus syndrome patients in whom ventricular pacing is indicated, switching between normal AV conduction and ventricular pacing should be minimized to avoid periods of repolarization instability.