MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-021-02023-5

Медицинская библиотека · International ophthalmology · 2021

Transscleral cyclophotocoagulation with MicroPulse® laser versus cyclophotocoagulation with continuous diode laser in patients with open-angle glaucoma.

Fili Sofia, Vastardis Iraklis, Perdikakis Georgios, Kohlhaas Markus

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To present the efficacy and safety of surgical treatment of moderate to advanced stage of open-angle glaucoma using the surgical method of transscleral cyclophotocoagulation with MicroPulse® laser (Iridex, Silicon Valley, California, USA) and to compare these results with those of continuous transscleral cyclophotocoagulation with diode laser.

METHODS

In a prospective observational clinical study 22 patients (30 eyes) with moderate and advanced open-angle glaucoma underwent transscleral cyclophotocoagulation. 15 eyes were treated with transscleral cyclophotocoagulation with MicroPulse® laser with 2500 mW (group A) and 15 eyes with continuous diode laser 810 nm and power between 2000 and 2300 mW (group B). The follow-up period of the study was 12 months.

RESULTS

A reduction of the intraocular pressure > 30% was achieved in 53.3% of the group A and in 60% of the group B during the follow-up period of 12 months. A statistically significant decrease of the number of antiglaucoma agents was observed in group A. One eye (6.6%) of group A underwent additional antiglaucoma procedures to achieve target intraocular pressure. The corresponding percentage is 40% in group B. The postoperative inflammatory response was significantly more limited in group A compared to group B.

CONCLUSIONS

The transscleral cyclophotocoagulation with MicroPulse® diode laser with 2500 mW achieves a similar decrease of the intraocular pressure as cyclophotocoagulation with continuous diode laser for the first postoperative months, but more satisfactory reduction of the number of eye drops as well as more limited postoperative inflammatory response.

Для цитирования: Fili Sofia, Vastardis Iraklis, Perdikakis Georgios, Kohlhaas Markus. Transscleral cyclophotocoagulation with MicroPulse® laser versus cyclophotocoagulation with continuous diode laser in patients with open-angle glaucoma.. International ophthalmology. 2021. DOI: 10.1007/s10792-021-02023-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.