MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.10.11.1

Медицинская библиотека · Translational vision science & technology · 2021

On Clinical Agreement on the Visibility and Extent of Anatomical Layers in Digital Gonio Photographs.

Peroni Andrea, Paviotti Anna, Campigotto Mauro, Abegão Pinto Luis, Cutolo Carlo Alberto, Shi Yue, Cobb Caroline, Gong Jacintha, Patel Sirjhun, Gillan Stewart, Tatham Andrew, Trucco Emanuele

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To quantitatively evaluate the inter-annotator variability of clinicians tracing the contours of anatomical layers of the iridocorneal angle on digital gonio photographs, thus providing a baseline for the validation of automated analysis algorithms.

METHODS

Using a software annotation tool on a common set of 20 images, five experienced ophthalmologists highlighted the contours of five anatomical layers of interest: iris root (IR), ciliary body band (CBB), scleral spur (SS), trabecular meshwork (TM), and cornea (C). Inter-annotator variability was assessed by (1) comparing the number of times ophthalmologists delineated each layer in the dataset; (2) quantifying how the consensus area for each layer (i.e., the intersection area of observers' delineations) varied with the consensus threshold; and (3) calculating agreement among annotators using average per-layer precision, sensitivity, and Dice score.

RESULTS

The SS showed the largest difference in annotation frequency (31%) and the minimum overall agreement in terms of consensus size (∼28% of the labeled pixels). The average annotator's per-layer statistics showed consistent patterns, with lower agreement on the CBB and SS (average Dice score ranges of 0.61-0.7 and 0.73-0.78, respectively) and better agreement on the IR, TM, and C (average Dice score ranges of 0.97-0.98, 0.84-0.9, and 0.93-0.96, respectively).

CONCLUSIONS

There was considerable inter-annotator variation in identifying contours of some anatomical layers in digital gonio photographs. Our pilot indicates that agreement was best on IR, TM, and C but poorer for CBB and SS.

TRANSLATIONAL RELEVANCE: This study provides a comprehensive description of inter-annotator agreement on digital gonio photographs segmentation as a baseline for validating deep learning models for automated gonioscopy.

Для цитирования: Peroni Andrea, Paviotti Anna, Campigotto Mauro, Abegão Pinto Luis, Cutolo Carlo Alberto, Shi Yue, Cobb Caroline, Gong Jacintha, Patel Sirjhun, Gillan Stewart, Tatham Andrew, Trucco Emanuele. On Clinical Agreement on the Visibility and Extent of Anatomical Layers in Digital Gonio Photographs.. Translational vision science & technology. 2021. DOI: 10.1167/tvst.10.11.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.