MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-021-92233-9

Медицинская библиотека · Scientific reports · 2021

A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma.

Giannaccare Giuseppe, Pellegrini Marco, Bernabei Federico, Urbini Lara, Bergamini Fulvio, Ferro Desideri Lorenzo, Bagnis Alessandro, Biagini Francesco, Cassottana Paola, Del Noce Chiara, Carnevali Adriano, Scorcia Vincenzo, Traverso Carlo E, Vagge Aldo

СтатьяПеревод пока не подготовлен

Аннотация

Ultrasound cyclo plasty (UCP) is a recently developed surgical technique for glaucoma allowing a selective and controlled coagulation of the ciliary body. We herein investigated the long-term efficacy and safety of UCP for the treatment of glaucoma. This prospective study included patients with primary and secondary glaucoma. All surgeries were performed using the EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France). Sixty-six patients were included, and 60 completed regularly the 2-year follow-up. Preoperative IOP was 28.5 ± 9.6 mmHg and significantly decreased to 17.0 ± 5.4 at 2 years (p < 0.001). The daily number of both hypotensive eye drops and acetazolamide tablets decreased significantly (respectively, from 2.6 ± 1.1 to 1.7 ± 1.2 and from 0.7 ± 0.8 to 0.2 ± 0.5; both p < 0.001). At 2 years, 68.1% of patients met the definition of qualified success (IOP < 21 mmHg regardless of glaucoma medications) and 10.3% of patients met the definition of complete success (IOP < 21 mmHg without glaucoma medications). No major intra- or postoperative complications occurred; however, 15 eyes required additional glaucoma surgery. These results suggest that UCP is an effective and safe procedure to reduce IOP in glaucoma patients through a 2-year follow-up period.

Для цитирования: Giannaccare Giuseppe, Pellegrini Marco, Bernabei Federico, Urbini Lara, Bergamini Fulvio, Ferro Desideri Lorenzo, Bagnis Alessandro, Biagini Francesco, Cassottana Paola, Del Noce Chiara, Carnevali Adriano, Scorcia Vincenzo, Traverso Carlo E, Vagge Aldo. A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma.. Scientific reports. 2021. DOI: 10.1038/s41598-021-92233-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.