MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2021.03.002

Медицинская библиотека · Ultrasound in medicine & biology · 2021

Repeatability and Reliability of Quantified Ultrasound Biomicroscopy Image Analysis of the Ciliary Body at the Pars Plicata.

Li Joy, Drechsler Jennifer, Lin Anna, Widlus Matthew, Qureshi Azam, Stoleru Gianna, Saeedi Osamah, Levin M Roni, Kaleem Mona, Jaafar Mohamad, Madigan William P, Alexander Janet Leath

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Most of the ciliary body and ciliary processes of the eye cannot be directly visualized in vivo because of the posterior location of the pars plicata to the posterior chamber and iris. However, ciliary anatomy can be effectively imaged using ultrasound biomicroscopy (UBM) by placing the probe close to the limbus, perpendicular to this structure. Previous studies measuring ciliary body parameters in meridian UBM images found that these parameters were measured with poor reliability and repeatability. This study evaluates the intra-observer reliability and inter-observer agreement of a standardized protocol for measuring six ciliary parameters in transverse or quadrant UBM images that capture an entire row of ciliary processes. All six ciliary parameters have high intra-observer reliability, with ciliary body thickness, ciliary process length and ciliary process density measurements being the most consistent for each observer. The coefficient of variation for each observer ranged from 1.4%-15%. Inter-observer agreement was also high for all six parameters, with an intra-class correlation coefficient >0.8. Utilizing transverse UBM images of the pars plicata allows for consistent quantitative analysis in control subjects.

Для цитирования: Li Joy, Drechsler Jennifer, Lin Anna, Widlus Matthew, Qureshi Azam, Stoleru Gianna, Saeedi Osamah, Levin M Roni, Kaleem Mona, Jaafar Mohamad, Madigan William P, Alexander Janet Leath. Repeatability and Reliability of Quantified Ultrasound Biomicroscopy Image Analysis of the Ciliary Body at the Pars Plicata.. Ultrasound in medicine & biology. 2021. DOI: 10.1016/j.ultrasmedbio.2021.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.