m+Medelevator.RU
← Поиск публикаций
Clinical oral investigations · 2024

Resonance frequency analysis of dental implants in patients with vitamin D deficiency.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Toy Vesile Elif, Sabancı Arife

Аннотация

OBJECTIVES: Vitamin D deficiency may influence dental implant osseointegration unfavourably. The aim of this study was to compare dental implant stabilities of patients with different levels of vitamin D and investigate the effects of vitamin D supplementation.

MATERIALS AND METHODS: One hundred and twenty-nine patients who underwent dental implantation were grouped regarding vitamin D levels and supplement use: Group A; vitamin D deficiency and supplement usage, Group B; insufficiency with supplement usage, Group C; insufficiency without supplements and Group D; vitamin D sufficiency. Resonance frequency analysis (RFA) measurements were performed at baseline and 3 months. Patients with vitamin D deficiency (Group A) and insufficiency (Group B) were prescribed supplements by specialists. Pearson correlation analysis was used to examine an association between vitamin D levels and implant stability.

RESULTS: Primary stability of Group D (76.34 ± 6.55) was significantly higher than Groups A, B and C at baseline (p < 0.05). At 3 months, Group C scored significantly lower than the other groups (p < 0.05). The results revealed a correlation between serum levels of vitamin D and RFA measurements at 3 months (p < 0.05).

CONCLUSION: It was observed that high vitamin D levels influenced implant stabilities positively, as evidenced by higher Implant Stability Quotient values. Low levels of vitamin D may be associated with a decrease in implant stability.

STATEMENT OF CLINICAL RELEVANCE: Vitamin D, concerning its impact on bone metabolism, is currently of particular interest in implant dentistry. The lower stability scores in patients with vitamin D deficiency reinforce the recommendation of Vitamin D supplementation when treating those patients with dental implants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты