Quality improvement to decrease specimen mislabeling in transfusion medicine.

Quillen Karen, Murphy Kate

СтатьяПеревод пока не подготовлен

Аннотация

CONTEXT: Proper specimen identification and labeling is a critical preanalytic step in pretransfusion compatibility testing.

OBJECTIVE

To gather baseline data for specimen mislabeling, specifically targeting major mislabeling events, and to design and implement a plan of corrective action.

DESIGN

All mislabeled specimens received by the transfusion service for a type and screen were recorded and classified into minor and major mislabeling categories. Major mislabeling events were tracked by origin of the specimen. Locations with a high proportion of major mislabeling were given timely feedback (within 1 week) of the events as they arose.

SETTING

A university hospital.

MAIN OUTCOME MEASURES: The incidence of major mislabeling.

RESULTS

The incidence of mislabeling in the transfusion service was 0.5% (243/49 955) during 21 months of data collection. Of these mislabeling events, 47% were classified as major events (unlabeled, mismatched specimen/ requisition, ABO/Rh result on current specimen not matching historical record on file). The emergency department accounted for a high proportion of these major mislabeling events. After the intervention of providing weekly feedback to emergency department staff, their contribution to major mislabeling fell from 47% in 1 year (23/49) to 14% (4/29) in the subsequent 3 quarters.

CONCLUSIONS

Collecting and trending data on mislabeled samples with timely feedback to patient care areas can change phlebotomy practice and reduce specimen mislabeling.

Для цитирования: Quillen Karen, Murphy Kate. Quality improvement to decrease specimen mislabeling in transfusion medicine.. Archives of pathology & laboratory medicine. 2006. DOI: 10.5858/2006-130-1196-qitdsm.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.