Factors Associated With Discordant Blood Pressure Measures among Very Old Adults: Results From the Atherosclerosis Risk in Communities (ARIC) Study.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Larbi Kwapong Fredrick, Grobman Benjamin, Col Hannah, Khan Md Marufuzzaman, Patil Dhrumil, Aidoo Emily L, Zhang Mingyu, Turkson-Ocran Ruth-Alma N, Ngo Long, Cluett Jennifer L, Mukamal Kenneth, Selvin Elizabeth, Lutsey Pamela L, Windham B Gwen, Mosley Thomas H, Wagenknecht Lynne E, Hughes Timothy, Coresh Josef, Ring Kim, Valint Arielle, Juraschek Stephen P
Аннотация
BACKGROUND: Home blood pressure (BP) monitoring (HBPM) is increasingly used as an alternative to office BP. However, factors influencing agreement between office and home BP among very old adults remain unclear.
METHODS: During ARIC (Atherosclerosis Risk in Communities) visit 10, participants underwent 3 automated office BP (AOBP) measurements using an Omron HEM-907XL and performed HBPM twice daily for 8 days using an Omron BP7450. Discordance was defined as a systolic BP difference of ±10 mm Hg between mean AOBP and HBPM. Multivariable regression models evaluated demographic, anthropometric, and clinical factors associated with discordance.
RESULTS: Among 792 participants (58% female; mean age, 84±3.7 years), mean systolic BP was 130.6 mm Hg (AOBP) and 129.6 mm Hg (HBPM). Despite a minimal average difference (1.0±15.7 mm Hg), 49% had ≥10 mm Hg systolic BP discordance. Higher AOBP was associated with greater discordance. Compared with females, males had lower AOBP relative to HBPM (-4.69 mm Hg [95% CI, -6.86 to -2.51]). Smaller arm circumference was associated with higher discordance (β=14.4 mm Hg [95% CI, 4.78-24.04]). Frail adults had lower AOBP relative to HBPM (β, -5.1 mm Hg [95% CI, -11.0 to 0.9]). Baseline AOBP systolic BP ≥140 mm Hg strongly predicted discordance ≥+10 mm Hg (odds ratio, 8.27 [95% CI, 5.52-12.40]). Participants aged 91 to 100 years had lower AOBP than those aged 78 to 80 years (β, -5.0 mm Hg [95% CI, -10.06 to 0.001]).
CONCLUSIONS: Among very old adults, substantial BP discordance between AOBP and HBPM was common and influenced by higher BP, age, male sex, arm circumference, and frailty.
METHODS: During ARIC (Atherosclerosis Risk in Communities) visit 10, participants underwent 3 automated office BP (AOBP) measurements using an Omron HEM-907XL and performed HBPM twice daily for 8 days using an Omron BP7450. Discordance was defined as a systolic BP difference of ±10 mm Hg between mean AOBP and HBPM. Multivariable regression models evaluated demographic, anthropometric, and clinical factors associated with discordance.
RESULTS: Among 792 participants (58% female; mean age, 84±3.7 years), mean systolic BP was 130.6 mm Hg (AOBP) and 129.6 mm Hg (HBPM). Despite a minimal average difference (1.0±15.7 mm Hg), 49% had ≥10 mm Hg systolic BP discordance. Higher AOBP was associated with greater discordance. Compared with females, males had lower AOBP relative to HBPM (-4.69 mm Hg [95% CI, -6.86 to -2.51]). Smaller arm circumference was associated with higher discordance (β=14.4 mm Hg [95% CI, 4.78-24.04]). Frail adults had lower AOBP relative to HBPM (β, -5.1 mm Hg [95% CI, -11.0 to 0.9]). Baseline AOBP systolic BP ≥140 mm Hg strongly predicted discordance ≥+10 mm Hg (odds ratio, 8.27 [95% CI, 5.52-12.40]). Participants aged 91 to 100 years had lower AOBP than those aged 78 to 80 years (β, -5.0 mm Hg [95% CI, -10.06 to 0.001]).
CONCLUSIONS: Among very old adults, substantial BP discordance between AOBP and HBPM was common and influenced by higher BP, age, male sex, arm circumference, and frailty.