MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/olq.0b013e318205491a

Медицинская библиотека · Sexually transmitted diseases · 2011

Evaluation of an IgM/IgG sensitive enzyme immunoassay and the utility of index values for the screening of syphilis infection in a high-risk population.

Wong Ernest H, Klausner Jeffrey D, Caguin-Grygiel Gloria, Madayag Carmela, Barber Kim O, Qiu Julia S, Liska Sally, Pandori Mark W

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Increasing interest in the use of enzyme immunoassays (EIA) for syphilis screening has generated a considerable need for data on the performance of such tests.

METHODS

We compared the performance of 1 EIA, the TREP-SURE EIA to that of the Venereal Disease Research Laboratory (VDRL) and Treponema pallidum particle agglutination assay (TPPA) in the detection of infection with Treponema pallidum. In total, 674 specimens were tested by VDRL and EIA (356 VDRL-nonreactive and 318 VDRL-reactive). All specimens that were found to be reactive by either the VDRL or EIA were subsequently analyzed by TPPA.

RESULTS

We found that the TREP-SURE EIA was marginally less sensitive than the VDRL test for screening, but was significantly more specific. All EIA-TPPA discordant specimens were analyzed by multiple tests, including Immunoglobulin M- and G-specific Western blots and an IgM-specific EIA. Signal-to-cutoff ratios (index values) generated by the TREP-SURE EIA were also investigated. It was found that these values may be instructive regarding the interpretation of test results, as they were found to correlate strongly with the probability of positivity on a TPPA assay. Specimens that reacted positively on the EIA with very high index values were found overwhelmingly to be reactive by TPPA, perhaps obviating the need for the testing of most EIA positive specimens with a secondary treponemal test.

CONCLUSIONS

An IgM/IgG sensitive EIA would be an effective alternative to VDRL for syphilis screening. Using the EIA index values may provide additional, helpful information to the diagnostic process.

Для цитирования: Wong Ernest H, Klausner Jeffrey D, Caguin-Grygiel Gloria, Madayag Carmela, Barber Kim O, Qiu Julia S, Liska Sally, Pandori Mark W. Evaluation of an IgM/IgG sensitive enzyme immunoassay and the utility of index values for the screening of syphilis infection in a high-risk population.. Sexually transmitted diseases. 2011. DOI: 10.1097/olq.0b013e318205491a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.