BACKGROUND

Because of limitations of conventional tools for diagnosing optic neuritis (ON), transorbital ultrasonography (TOUS) was introduced as a promising tool to evaluate the optic nerve. However, studies demonstrating its utility are scarce.

OBJECTIVE

To assess the practical diagnostic value of TOUS in patients with ON along with other diagnostic tools such as visual evoked potential (VEP), MRI, and optical coherence tomography (OCT).

METHODS

Seventeen patients with first-attack unilateral acute ON were enrolled. Clinical characteristics, visual acuity, TOUS, MRI, VEP, and OCT results were evaluated. Bilateral optic nerves were scanned using TOUS to obtain axial images showing the optic nerve and the disc in the longitudinal plane.

RESULTS

TOUS revealed thickening of the optic nerve sheath and optic nerve diameter with sheath on the affected side compared with the unaffected side (p = 0.002 and p = 0.003, respectively). Time since onset of initial symptoms was inversely correlated with optic nerve diameter (ρ = -0.517, p = 0.040) and retinal nerve fiber layer thickness (ρ = -0.831, p < 0.001).

CONCLUSION

TOUS could be a cost-effective tool for morphologically evaluating acute ON showing a significant thickening of the optic nerve and sheath, although only a limited retrobulbar area could be explored.

Для цитирования: Kwon Ye-Ji, Kim Yoo Hwan, Baek Seol-Hee, Son Myeong Hun, Lee Jung Hun, Kim Byung-Jo. Transorbital ultrasonography in acute optic neuritis: Can it be a supportive diagnostic tool?. Multiple sclerosis and related disorders. 2019. DOI: 10.1016/j.msard.2019.03.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.