MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10916-023-02002-6

Медицинская библиотека · Journal of medical systems · 2023

Radio Frequency Identification Gate System to Identify Misused Personal Dosimeters.

Tamura Megumi, Kawamoto Takeshi, Ishifuro Minoru, Tamura Takayuki, Masumoto Yoshifumi, Kenjo Masahiro, Kiguchi Masao, Awai Kazuo, Nagata Yasushi

СтатьяПеревод пока не подготовлен

Аннотация

The use of two personal dosimeters, one worn over and one worn under a protective apron, provides the best estimate of effective dose. However, inappropriate positioning of dosimeters is a common occurrence, resulting in abnormally high or low radiation exposure records. Although such incorrect positioning can be identified by radiation exposure records, doing so is time-consuming and labor-intensive for administrators. Therefore, a system that can identify incorrect locations of dosimeters without burdening administrators must be developed. In this study, we developed a radio frequency identification (RFID) gate system that can differentiate between two RFID-tagged dosimeters placed over and under a metal apron and identify misused dosimeters. To simulate the position of the RFID-tagged dosimeters, we designed four dosimeter-wearing classes, including "proper use" and three types of "misuse" (i.e., "reversed," "both under," and "both over"). When the system predicts "misuse" based on the tag reading, the worker is alerted with lights and alarms. The system performance was evaluated using a confusion matrix, with an overall accuracy of 97.75%, demonstrating high classification performance. The safety of the system against life support devices was also investigated, demonstrating that they were not affected by the electric field at 0.3 m or more from the antenna of the system under any transmit powers tested. This RFID gate system is highly capable of identifying incorrectly positioned dosimeters, enabling real-time monitoring of dosimeters to manage their positioning.

Для цитирования: Tamura Megumi, Kawamoto Takeshi, Ishifuro Minoru, Tamura Takayuki, Masumoto Yoshifumi, Kenjo Masahiro, Kiguchi Masao, Awai Kazuo, Nagata Yasushi. Radio Frequency Identification Gate System to Identify Misused Personal Dosimeters.. Journal of medical systems. 2023. DOI: 10.1007/s10916-023-02002-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.