Аннотация

BACKGROUND

The Centers for Disease Control and Prevention have recently introduced new ventilator-associated pneumonia (VAP) surveillance on the basis of the infection-related ventilator-associated complication (IVAC) definition. We aim to evaluate the accuracy of this new IVAC algorithm for detecting VAP according to the 2008 Centers for Disease Control and Prevention/National Healthcare Safety Network (NHSN) definition as the reference diagnosis (VAP-NHSN) in high-risk trauma patients.

METHODS

This retrospective single-center study included all trauma subjects who were admitted to the ICU, required mechanical ventilation for >48 h, and received a blood transfusion. The new IVAC surveillance and the criteria for VAP-NHSN diagnosis were applied. The accuracy of the new IVAC surveillance for detecting VAP-NHSN was determined, and the clinical outcomes were compared between groups.

RESULTS

The sensitivity, specificity, and positive and negative predictive values of IVAC for VAP-NSHN identification were 28.12%, 91.45, 58.06%, and 75.14%, respectively. Subjects with IVAC, VAP-NHSN, or both had higher morbidity when compared with those without IVAC and VAP-NHSN. Subjects with IVAC only had lower morbidity compared with those with VAP-NHSN only or those with both IVAC and VAP-NHSN. There was no significant difference in clinical outcomes between subjects with VAP-NHSN only and those with both IVAC and VAP-NHSN.

CONCLUSIONS

IVAC criteria had a low accuracy for identifying VAP-NHSN in subjects with high-risk trauma.

Для цитирования: Piriyapatsom Annop, Lin Hsin, Pirrone Massimiliano, De Pascale Gennaro, Corona De Lapuerta Javier, Bittner Edward A, Schmidt Ulrich H, De Moya Marc, Berra Lorenzo. Evaluation of the Infection-Related Ventilator-Associated Events Algorithm for Ventilator-Associated Pneumonia Surveillance in a Trauma Population.. Respiratory care. 2015. DOI: 10.4187/respcare.04280.