MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aln.0b013e318182c855

Медицинская библиотека · Anesthesiology · 2008

Transmission of pathogenic bacterial organisms in the anesthesia work area.

Loftus Randy W, Koff Matthew D, Burchman Corey C, Schwartzman Joseph D, Thorum Valerie, Read Megan E, Wood Tammara A, Beach Michael L

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The current prevalence of hospital-acquired infections and evolving amplification of bacterial resistance are major public health concerns. A heightened awareness of intraoperative transmission of potentially pathogenic bacterial organisms may lead to implementation of effective preventative measures.

METHODS

Sixty-one operative suites were randomly selected for analysis. Sterile intravenous stopcock sets and two sites on the anesthesia machine were decontaminated and cultured aseptically at baseline and at case completion. The primary outcome was the presence of a positive culture on the previously sterile patient stopcock set. Secondary outcomes were the number of colonies per surface area sampled on the anesthesia machine, species identification, and antibiotic susceptibility of isolated organisms.

RESULTS

Bacterial contamination of the anesthesia work area increased significantly at the case conclusion, with a mean difference of 115 colonies per surface area sampled (95% confidence interval [CI], 62-169; P < 0.001). Transmission of bacterial organisms, including vancomycin-resistant enterococcus, to intravenous stopcock sets occurred in 32% (95% CI, 20.6-44.9%) of cases. Highly contaminated work areas increased the odds of stopcock contamination by 4.7 (95% CI, 1.42-15.42; P = 0.011). Contaminated intravenous tubing was associated with a trend toward increased nosocomial infection rates (odds ratio, 3.08; 95% CI, 0.56-17.5; P = 0.11) and with an increase in mortality (95% CI odds ratio, 1.11-infinity; P = 0.0395).

CONCLUSION

Potentially pathogenic, multidrug-resistant bacterial organisms are transmitted during the practice of general anesthesia to both the anesthesia work area and intravenous stopcock sets. Implementation of infection control measures in this area may help to reduce both the evolving problem of increasing bacterial resistance and the development of life-threatening infectious complications.

Для цитирования: Loftus Randy W, Koff Matthew D, Burchman Corey C, Schwartzman Joseph D, Thorum Valerie, Read Megan E, Wood Tammara A, Beach Michael L. Transmission of pathogenic bacterial organisms in the anesthesia work area.. Anesthesiology. 2008. DOI: 10.1097/aln.0b013e318182c855.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.