MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10903129808958850

Медицинская библиотека · Prehospital emergency care · 1998

Choice of airway devices for 12,020 cases of nontraumatic cardiac arrest in Japan.

Tanigawa K, Shigematsu A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

This retrospective study was designed to determine the choice of airway devices used for nontraumatic, out-of-hospital cardiac arrest patients and to evaluate the success and failure of insertion and airway control/ventilation by three airway adjuncts, the Combitube, the esophageal gastric tube airway (EGTA), and the laryngeal mask (LM), which were used in conjunction with the bag-valve-mask (BVM) by emergency life-saving technicians (ELSTs) in Japan.

METHODS

A survey of 1,085 ELSTs was performed to identify the type of airway devices, the success rates of airway insertion, the effectiveness of airway control/ventilation in comparison with the BVM prior to each airway insertion, and associated complications. The type of education for airway skills was also surveyed.

RESULTS

1,079 surveys were returned and 12,020 cases of cardiac arrest were studied. Choice of airway devices: BVM, 7,180 cases; EGTA, 545 cases; Combitube, 1,594 cases; and LM, 2,701 cases. Successful insertion rates on the first attempt: EGTA, 82.7%; Combitube, 82.4%; and LM, 72.5% (p < 0.0001). Failed insertions: EGTA, 8.2%; Combitube, 6.9%; and LM, 10.5% (p < 0.0001). Successful ventilation: EGTA, 71.0%; Combitube, 78.9%; and LM, 71.5% (p < 0.0004). Six cases of aspiration were reported in the LM group, whereas nine cases of soft-tissue injuries, including esophageal perforation, were reported in the Combitube group. 17.8% had vomited either prior or during airway placement.

CONCLUSION

The Combitube appears to be the most appropriate choice among the airway devices examined. However, serious injuries to the tissues, though they rarely occurred in the study, remain a major concern.

Для цитирования: Tanigawa K, Shigematsu A. Choice of airway devices for 12,020 cases of nontraumatic cardiac arrest in Japan.. Prehospital emergency care. 1998. DOI: 10.1080/10903129808958850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.