MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-021-07893-y

Медицинская библиотека · European radiology · 2021

Assessment of blood supply of the external carotid artery in moyamoya disease using super-selective pseudo-continuous arterial spin labeling technique.

Yuan Jing, Qu Jianxun, Lv Zheng, Wu Chunxue, Zhang Dong, Liu Xingju, Yang Bao, Liu Yaou

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the diagnostic accuracy of super-selective pseudo-continuous arterial spin labeling (ss-pCASL) at depicting external carotid artery (ECA) perfusion territory in moyamoya disease (MMD).

METHODS

In total, 103 patients with MMD who underwent both ss-pCASL and digital subtraction angiography (DSA, the reference standard) were included. There were 3, 184, and 19 normal, preoperative, and postoperative MMD hemispheres, respectively. The ss-pCASL results were interpreted by two different visual inspection criteria: presence or absence and definite or indefinite ECA perfusion territory. The performance of ss-pCASL at depiction of ECA perfusion territory was compared to that of DSA. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. The κ statistic was used to assess intermodality and inter-reader agreement.

RESULTS

When interpreted as presence or absence, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of ss-pCASL for depicting ECA perfusion territory were 78.3 %, 79.6 %, 92.5 %, 53.4 %, and 78.6 %, respectively, and the intermodality and inter-reader agreement were κ = 0.49 (CI: 0.43 - 0.55, p < 0.01) and 0.71 (CI: 0.66 - 0.76, p < 0.01), respectively. When interpreted as definite or indefinite, the respective values were 61.1%, 100%, 100%, 44.5%, 70.4%, κ = 0.42 (CI: 0.37 - 0.47, p < 0.01), and 0.90 (CI: 0.87 - 0.93, p < 0.01).

CONCLUSION

ss-pCASL has substantial sensitivity and specificity compared with DSA for depicting the presence versus absence of ECA perfusion territory in MMD. As a noninvasive method in which no ion radiation or contrast medium is needed, ss-pCASL may potentially reduce the need for repeated DSA examination.

KEY POINTS: • Super-selective pseudo-continuous arterial spin labeling (ss-pCASL) is a noninvasive vessel-selective MR technique to demonstrate perfusion territory of a single cerebral artery. • Compared with digital subtraction angiography, ss-pCASL has substantial sensitivity and specificity for depicting the perfusion territory of the external carotid artery in brain parenchyma in moyamoya disease. • ss-pCASL may potentially reduce the need for repeated DSA examination.

Для цитирования: Yuan Jing, Qu Jianxun, Lv Zheng, Wu Chunxue, Zhang Dong, Liu Xingju, Yang Bao, Liu Yaou. Assessment of blood supply of the external carotid artery in moyamoya disease using super-selective pseudo-continuous arterial spin labeling technique.. European radiology. 2021. DOI: 10.1007/s00330-021-07893-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.