MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2025.06.048

Медицинская библиотека · Annals of vascular surgery · 2025

Comparative Outcomes of Paclitaxel-Coated Balloons and Simple Plain Balloon Angioplasty in the Treatment of Infrainguinal Bypass Anastomotic Stenosis.

Videira Mariana, Mendes Daniel, Pinelo Andreia, Machado Rui

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Paclitaxel-coated balloons (PCBs) have shown increasing efficacy in the treatment of stenosis across different vascular territories. However, their specific role in the management of bypass graft stenosis remains poorly defined. This study aimed to compare clinical outcomes of PCBs versus simple plain balloon angioplasty (PBA) in treating infrainguinal bypass graft anastomotic stenosis.

METHODS

A retrospective single-center cohort study was conducted including all interventions for infrainguinal prosthetic and vein bypass graft anastomotic stenosis between 2014 and 2023. Demographic characteristics, clinical, interventional, and follow-up data were obtained from medical records. The primary end point was reintervention-free survival at 24 months. Secondary end points included freedom from target lesion revascularization, major amputation, and mortality rates. Multivariate analyses were performed, along with secondary analyses based on the graft type (venous or prosthetic) and graft status (thrombosed or failing).

RESULTS

Eighty-three patients who underwent a total of 116 interventions (46 PCBs and 70 PBA procedures) were included. Reintervention-free survival at 24 months was significantly higher in the PCB group compared to the PBA group (64.1% vs. 43.6%; P = 0.007). Multivariate analysis identified adequate runoff (hazard ratio [HR] = 0.56; 95% confidence interval [CI]: 0.32-0.99; P = 0.046) and the use of drug-eluting balloons (HR = 0.48; 95% CI: 0.26-0.88; P = 0.017) as independent predictors of improved reintervention-free survival. Freedom from target lesion revascularization was also significantly higher in the PCB group (67.8% vs. 51.5%; P = 0.024). There were no significant differences in the rates of major amputation (22.8% vs. 25.0%; P = 1) or mortality (5.7% vs. 10.4%; P = 0.567) between patients treated with or without PCBs, respectively.

CONCLUSION

The use of PCBs in the treatment of infrainguinal bypass graft anastomotic stenosis appears to be associated with improved freedom from the composite end point of reintervention, amputation, or death, compared to PBA alone.

Для цитирования: Videira Mariana, Mendes Daniel, Pinelo Andreia, Machado Rui. Comparative Outcomes of Paclitaxel-Coated Balloons and Simple Plain Balloon Angioplasty in the Treatment of Infrainguinal Bypass Anastomotic Stenosis.. Annals of vascular surgery. 2025. DOI: 10.1016/j.avsg.2025.06.048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.