Valve-in-valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement in patients with degenerated aortic bioprostheses: Three-year death rates and haemodynamic performance.

Rosier Grégoire, Guimbretière Guillaume, Guérin Patrice, Bouquin Claire, Delépine Stéphane, Pinaud Frédéric, Rouleau Frédéric, Sénage Thomas, Roussel Jean Christian, Riou Jérémie, Le Tourneau Thierry, Bière Loïc

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Management of degenerated aortic bioprostheses through valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) or redo surgical aortic valve replacement (Re-SAVR) shows similar short-term safety and efficacy. However, long-term survival and haemodynamic performance data are limited.

AIM: To compare clinical characteristics, haemodynamics and outcomes at 3 years between ViV-TAVR and Re-SAVR techniques.

METHODS

This retrospective two-centre study included 266 patients treated for isolated aortic bioprosthesis degeneration (130 Re-SAVR, 136ViV-TAVR) from 2009 to 2018, with up to 3 years of follow-up.

RESULTS

The ViV-TAVR group was older (83 vs. 77 years; P=0.005) with higher surgical risk (Logistic EuroSCORE 22% vs. 13%; P=0.005). At 3 years, univariate analysis showed no significant difference in all-cause deaths (22.1% vs. 17.7%; P=0.37). ViV-TAVR was associated with fewer first-month complications, including major bleeding (11.0% vs. 52.3%; P=0.007) and acute renal failure grade 2/3 (5.1% vs. 14.6%; P=0.053). Inverse probability of treatment weighting analysis revealed no difference in all-cause deaths at 1 year (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.36-1.67; P=0.52) or between 1 and 3 years (HR 1.56, 95% CI 0.82-2.99; P=0.17). Composite events were similar at 1 year (HR 0.80, 95% CI 0.44-1.44; P=0.45) and between 1 and 3 years (HR 1.41, 95% CI 0.83-2.38; P=0.21). Mean gradients at 3 years were similar (16.1±11.4 vs. 13.2±5.3mmHg; P=0.17). In patients with small bioprostheses (true internal diameter≤20mm [n=151]), death rates at 3 years were similar (21.1% vs. 20.0%; P=0.86), as was haemodynamic performance (mean gradient 19.2±14.0mmHg for ViV-TAVR vs. 13.7±4.12mmHg for Re-SAVR [P=0.38]). Compared to balloon-expandable, self-expandable valves showed better 1-year mean gradients (16.4±10.5 vs. 13.7±4.12mmHg; P=0.012).

CONCLUSIONS

ViV-TAVR and Re-SAVR had similar mortality and haemodynamic outcomes at 3 years, including in patients with small bioprostheses where self-expandable valves yielded the best results.

Для цитирования: Rosier Grégoire, Guimbretière Guillaume, Guérin Patrice, Bouquin Claire, Delépine Stéphane, Pinaud Frédéric, Rouleau Frédéric, Sénage Thomas, Roussel Jean Christian, Riou Jérémie, Le Tourneau Thierry, Bière Loïc. Valve-in-valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement in patients with degenerated aortic bioprostheses: Three-year death rates and haemodynamic performance.. Archives of cardiovascular diseases. 2025. DOI: 10.1016/j.acvd.2025.03.124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.