Routine Cerebral Embolic Protection during Transcatheter Aortic-Valve Implantation.

Kharbanda Rajesh K, Kennedy James, Jamal Zahra, Dodd Matthew, Evans Richard, Bal Kiran K, Perkins Alexander D, Blackman Daniel J, Hildick-Smith David, Banning Adrian P, Baumbach Andreas, Ludman Peter, Palmer Stephen, Stables Rodney H, Henderson Robert, Appleby Clare, Cotton James, Curzen Nick, Ozkor Muhiddin, Byrne Jonathan, Aggarwal Rajesh, Das Rajiv, Doshi Sagar, Watkins Stuart, Muir Douglas F, Anderson Richard, Chowdhary Saqib, Varcoe Richard, Dorman Stephen, Firoozi Sam, Chelliah Raj, Owens Colum, Redwood Simon, Prendergast Bernard, Iqbal Javaid, Ratib Karim, Dospinescu Ciprian, Suresh Venkatesan, Cruden Nicholas, Rajathurai Thirumaran, Malik Iqbal S, Wiper Andrew, Costopoulos Charis, Khurana Ayush, Banning Amerjeet, Clayton Tim, BHF PROTECT-TAVI Investigators

Клиническое исследование III фазыСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic-valve implantation (TAVI) is associated with procedure-related stroke. Cerebral embolic protection (CEP) devices may reduce embolization to the cerebral circulation and hence the incidence of stroke.

METHODS

We conducted a randomized, controlled trial across 33 centers in the United Kingdom. We randomly assigned 7635 participants with aortic stenosis in a 1:1 ratio to undergo TAVI with a CEP device (CEP group) or TAVI without a CEP device (control group). The primary outcome was stroke within 72 hours after TAVI or before discharge from the hospital (if discharge occurred sooner).

RESULTS

A total of 3815 participants were assigned to the CEP group and 3820 to the control group. A primary-outcome event occurred in 81 of 3795 participants (2.1%) in the CEP group and in 82 of 3799 participants (2.2%) in the control group (difference, -0.02 percentage points; 95% confidence interval, -0.68 to 0.63; P = 0.94). Disabling stroke occurred in 47 participants (1.2%) in the CEP group and in 53 (1.4%) in the control group. Death occurred in 29 participants (0.8%) in the CEP group and in 26 (0.7%) in the control group. Overall access-site complications appeared to be similar in the two groups (8.1% in the CEP group and 7.7% in the control group). A total of 24 serious adverse events occurred in 22 of 3798 participants (0.6%) in the CEP group, and 13 serious adverse events occurred in 13 of 3803 participants (0.3%) in the control group.

CONCLUSIONS

Among participants undergoing TAVI, routine use of CEP did not decrease the incidence of stroke within 72 hours. (Funded by the British Heart Foundation and Boston Scientific; BHF PROTECT-TAVI ISRCTN Registry number, ISRCTN16665769.).

Для цитирования: Kharbanda Rajesh K, Kennedy James, Jamal Zahra, Dodd Matthew, Evans Richard, Bal Kiran K, Perkins Alexander D, Blackman Daniel J, Hildick-Smith David, Banning Adrian P, Baumbach Andreas, Ludman Peter, Palmer Stephen, Stables Rodney H, Henderson Robert, Appleby Clare, Cotton James, Curzen Nick, Ozkor Muhiddin, Byrne Jonathan, Aggarwal Rajesh, Das Rajiv, Doshi Sagar, Watkins Stuart, Muir Douglas F, Anderson Richard, Chowdhary Saqib, Varcoe Richard, Dorman Stephen, Firoozi Sam, Chelliah Raj, Owens Colum, Redwood Simon, Prendergast Bernard, Iqbal Javaid, Ratib Karim, Dospinescu Ciprian, Suresh Venkatesan, Cruden Nicholas, Rajathurai Thirumaran, Malik Iqbal S, Wiper Andrew, Costopoulos Charis, Khurana Ayush, Banning Amerjeet, Clayton Tim, BHF PROTECT-TAVI Investigators. Routine Cerebral Embolic Protection during Transcatheter Aortic-Valve Implantation.. The New England journal of medicine. 2025. DOI: 10.1056/nejmoa2415120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.