MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/jtd-20-2562

Медицинская библиотека · Journal of thoracic disease · 2021

Outcomes related to anticoagulation management for mechanical valve replacements.

Huckaby Lauren V, Seese Laura M, Gleason Thomas G, Sultan Ibrahim, Wang Yisi, Thoma Floyd, Kilic Arman

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study evaluates anticoagulation management and its impact on longitudinal clinical outcomes in patients undergoing mechanical valve replacement.

METHODS

Patients undergoing mechanical mitral valve replacement (MVR) or aortic valve replacement (AVR) from 2010-2018 at a single center were included. Patients were stratified into therapeutic and non-therapeutic anticoagulation groups based on the median percentage of international normalized ratio (INR) values within the reference range (2.0-3.0 for AVR, 2.5-3.5 for MVR) during the first post-operative year. Using Cox regression analysis, comorbidity-adjusted survival and freedom from adverse events were compared.

RESULTS

Six hundred and fifty-one patients underwent mechanical valve replacement (166 MVR, 485 AVR). Comorbidity-adjusted survival was similar in the MVR and AVR cohorts (P=0.23). There was a median of 27 [interquartile range (IQR): 14-42] INRs drawn per patient in the first post-operative year. The median percentage of INRs within the reference values during the first post-operative year was 42.85% (IQR: 30.77-53.95%), with the majority of non-therapeutic INRs being subtherapeutic (34.51%; n=6,864). There were no significant differences in adjusted survival between the therapeutic and non-therapeutic groups [hazard ratio (HR): 1.12, P=0.73]. Within the first post-operative year, there were no significant differences in stroke, major bleeding, peripheral non-stroke arterial thromboembolism, and readmission for intravenous heparin in the therapeutic and non-therapeutic groups.

CONCLUSIONS

Taking into account relevant comorbidities and valve type, patients with a larger proportion of non-therapeutic INRs during the first post-operative year demonstrated no difference in longitudinal clinical outcomes. Further research into more standardized INR monitoring and potentially expanded INR target ranges for patients undergoing mechanical valve replacement is warranted.

Для цитирования: Huckaby Lauren V, Seese Laura M, Gleason Thomas G, Sultan Ibrahim, Wang Yisi, Thoma Floyd, Kilic Arman. Outcomes related to anticoagulation management for mechanical valve replacements.. Journal of thoracic disease. 2021. DOI: 10.21037/jtd-20-2562.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.