DOI 10.1177/2048004021999900

Медицинская библиотека · JRSM cardiovascular disease · 2021

Aortic and mitral flow quantification using dynamic valve tracking and machine learning: Prospective study assessing static and dynamic plane repeatability, variability and agreement.

Garcia Julio, Beckie Kailey, Hassanabad Ali F, Sojoudi Alireza, White James A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Blood flow is a crucial measurement in the assessment of heart valve disease. Time-resolved flow using magnetic resonance imaging (4 D flow MRI) can provide a comprehensive assessment of heart valve hemodynamics but it relies in manual plane analysis. In this study, we aimed to demonstrate the feasibility of automate the detection and tracking of aortic and mitral valve planes to assess blood flow from 4 D flow MRI.

METHODS

In this prospective study, a total of n = 106 subjects were enrolled: 19 patients with mitral disease, 65 aortic disease patients and 22 healthy controls. Machine learning was employed to detect aortic and mitral location and motion in a cine three-chamber plane and a perpendicular projection was co-registered to the 4 D flow MRI dataset to quantify flow volume, regurgitant fraction, and a peak velocity. Static and dynamic plane association and agreement were evaluated. Intra- and inter-observer, and scan-rescan reproducibility were also assessed.

RESULTS

Aortic regurgitant fraction was elevated in aortic valve disease patients as compared with controls and mitral valve disease patients (p < 0.05). Similarly, mitral regurgitant fraction was higher in mitral valve patients (p < 0.05). Both aortic and mitral total flow were high in aortic patients. Static and dynamic were good (r > 0.6, p < 0.005) for aortic total flow and peak velocity, and mitral peak velocity and regurgitant fraction. All measurements showed good inter- and intra-observer, and scan-rescan reproducibility.

CONCLUSION

We demonstrated that aortic and mitral hemodynamics can efficiently be quantified from 4 D flow MRI using assisted valve detection with machine learning.

Для цитирования: Garcia Julio, Beckie Kailey, Hassanabad Ali F, Sojoudi Alireza, White James A. Aortic and mitral flow quantification using dynamic valve tracking and machine learning: Prospective study assessing static and dynamic plane repeatability, variability and agreement.. JRSM cardiovascular disease. 2021. DOI: 10.1177/2048004021999900.