DOI 10.1016/j.jtcvs.2020.12.036
A conservative screening algorithm to determine candidacy for robotic mitral valve surgery.
Аннотация
OBJECTIVE
Patient selection for robotically assisted mitral valve repair remains controversial. We assessed outcomes of a conservative screening algorithm developed to select patients with degenerative mitral valve disease for robotic surgery.
METHODS
From January 2014 to January 2019, a screening algorithm that included transthoracic echocardiography and computed tomography scanning was rigorously applied by 3 surgeons to assess candidacy of 1000 consecutive patients with isolated degenerative mitral valve disease (age 58 ± 11 years, 67% male) for robotic surgery. Screening results and hospital outcomes of those selected for robotic versus sternotomy approaches were compared.
RESULTS
With application of the screening algorithm, 605 patients were selected for robotic surgery. Common reasons for sternotomy (n = 395) were aortoiliac atherosclerosis (n = 74/292, 25%), femoral artery diameter <7 mm (n = 60/292, 20%), mitral annular calcification (n = 83/390, 21%), aortic regurgitation (n = 100/391, 26%), and reduced left ventricular function (n = 126/391, 32%). Mitral valve repair was accomplished in 996. Compared with sternotomy, patients undergoing robotic surgery had less new-onset atrial fibrillation (n = 144/582, 25% vs n = 125/373, 34%; P = .002), fewer red blood cell transfusions (n = 61/601, 10% vs 69/395, 17%; P < .001), and shorter hospital stay (5.2 ± 2.9 days vs 5.9 ± 2.1 days; P < .001). No hospital deaths occurred, and occurrence of postoperative stroke in the robotic (n = 3/605, 0.50%) and sternotomy (n = 4/395, 1.0%; P = .3) groups was similar.
CONCLUSIONS
This conservative screening algorithm qualified 60% of patients with isolated degenerative mitral valve disease for robotic surgery. Outcomes were comparable with those obtained with sternotomy, validating this as an approach to select patients for robotic mitral valve surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.