MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2009.2.17680

Медицинская библиотека · Journal of neurosurgery. Spine · 2009

Postoperative displacement of hydroxyapatite spacers implanted during double-door laminoplasty.

Kaito Takashi, Hosono Noboru, Makino Takahiro, Kaneko Noriyoshi, Namekata Masato, Fuji Takeshi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECT: Double-door laminoplasty using hydroxyapatite (HA) spacers has been widely performed for compressive cervical myelopathy and has provided good neurological outcome. Although HA spacers are used for preventing reclosure of the opened laminae, they are often displaced or dislocated from their original position. The authors investigated the incidence and patterns of postoperative HA spacer displacement to determine the reasons for this unfavorable event.

METHODS

Eighty-six patients with compressive myelopathy underwent double-door laminoplasty in which a total of 278 HA spacers were used. The displacement of HA spacers and opened laminae were assessed using postoperative lateral radiographs and CT scans.

RESULTS

Postoperative dorsal migration > 2 mm was found in 116 (42%) of 278 implanted HA spacers. In addition, 33 (38%) of 86 HA spacers rotated > 10 degrees and 29 (34%) of the 86 opened laminae tilted > 10 degrees. Moreover, deformation of the newly formed spinal canal was observed in 51 (59%) of 86 cases, and bone fusion between the HA spacer and spinous process was achieved in only 15 (8.7%) of 172 cases. Neurological worsening and neck pain, however, were not associated with displacement of HA spacers or deformation of the spinal canal.

CONCLUSIONS

In double-door laminoplasty, postoperative displacement of the HA spacer with deformation of the enlarged spinal canal occurred frequently. Hydroxyapatite spacers tend to become displaced after surgery. Placing the HA spacer at the base of the spinous process close to the dura mater may prevent postoperative displacement.

Для цитирования: Kaito Takashi, Hosono Noboru, Makino Takahiro, Kaneko Noriyoshi, Namekata Masato, Fuji Takeshi. Postoperative displacement of hydroxyapatite spacers implanted during double-door laminoplasty.. Journal of neurosurgery. Spine. 2009. DOI: 10.3171/2009.2.17680.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.