Plaque echolucency is not associated with the risk of stroke in carotid stenting.

Reiter Markus, Bucek Robert A, Effenberger Isabella, Boltuch Johanna, Lang Wilfried, Ahmadi Ramazanali, Minar Erich, Schillinger Martin

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Plaque characteristics are suggested to play a potentially important role as risk factors for poor outcome after carotid artery stenting (CAS). We therefore correlated objectively and subjectively determined carotid plaque morphology with neurological complications after CAS.

METHODS

We enrolled 698 consecutive patients undergoing elective CAS from a prospective single-center registry database and classified the preinterventional plaque status according to gray-scale median levels and the standardized Beletsky and Gray-Weale plaque scores. Patients were followed for 30-day neurological complications.

RESULTS

Neurological complications including transient ischemic attack, minor and major stroke occurred in 5.9% (41/698) of the patients. Median gray-scale median, Beletsky and Gray-Weale scores were 45 (interquartile range [IQR] 25 to 70), 3.0 (IQR 2.0 to 3.0) and 2.0 (IQR 2.0 to 3.0), respectively. None of the scores was significantly associated with adverse outcome adjusting for traditional risk factors, medication, preinterventional symptoms, degree of stenosis, contralateral occlusion and use of cerebral protection, neither with respect to all neurological complications nor with respect to stroke and death (all P>0.05).

CONCLUSIONS

Plaque echolucency measured by objective and subjective grading did not identify patients with an increased risk of peri-interventional neurological events. Evaluation of plaque echolucency therefore cannot be recommended for risk stratification in CAS patients.

Для цитирования: Reiter Markus, Bucek Robert A, Effenberger Isabella, Boltuch Johanna, Lang Wilfried, Ahmadi Ramazanali, Minar Erich, Schillinger Martin. Plaque echolucency is not associated with the risk of stroke in carotid stenting.. Stroke. 2006. DOI: 10.1161/01.str.0000237087.86583.c8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.