Wu Wenjie, Su Qianya, Zhang Yuezhu, Du Yaxin, Hu Yakun, Wang Fei
Аннотация
BACKGROUND: Melasma is a common pigmentary and photoaging disorder. Although various treatments, including 1,064-nm Q-switched neodymium-doped yttrium aluminum garnet (QS-Nd: YAG) laser toning, are available for melasma, results are often unsatisfactory.
OBJECTIVE: We aimed to determine the efficacy and safety of 532-nm QS-Nd: YAG laser (shortwave toning) in patients with melasma and facial rejuvenation.
METHODS: Fifty-two patients were recruited to receive either 1,064-nm QS-Nd: YAG laser or 532-nm QS-Nd: YAG laser every 2 weeks for 8 sessions and a 2-month follow-up visit in a randomized controlled double-blinded study. The primary outcome measure was the Melasma Area and Severity Index (MASI) score. Dermoscope and high-frequency ultrasound (HFUS) were used to assess the improvement of melasma and photoaging.
RESULTS: 532-nm QS-Nd: YAG laser achieved significantly higher improvement in the MASI score (P = 0.000). The Dermoscopic melasma score (DMS) displayed significant change and confirmed the improvement. HFUS showed a significant decrease in the thickness of the subepidermal low-echogenic band (SLEB) and increases in dermal thickness and dermal density in both groups (P = 0.000 for all). The rate of very satisfied responses was significantly higher in the 532-nm laser group (P = 0.001). There was no significant difference in the visual analog scale pain assessment score (P = 0.248) and recurrence rate (P = 0.734) between the two groups.
CONCLUSION: 532-nm QS-Nd: YAG laser (shortwave toning) proved to be an effective and safe treatment for melasma and rejuvenation. Shortwave toning was significantly better for pigmentation clearance, while 1,064-nm laser showed better improvement in skin rejuvenation.
OBJECTIVE: We aimed to determine the efficacy and safety of 532-nm QS-Nd: YAG laser (shortwave toning) in patients with melasma and facial rejuvenation.
METHODS: Fifty-two patients were recruited to receive either 1,064-nm QS-Nd: YAG laser or 532-nm QS-Nd: YAG laser every 2 weeks for 8 sessions and a 2-month follow-up visit in a randomized controlled double-blinded study. The primary outcome measure was the Melasma Area and Severity Index (MASI) score. Dermoscope and high-frequency ultrasound (HFUS) were used to assess the improvement of melasma and photoaging.
RESULTS: 532-nm QS-Nd: YAG laser achieved significantly higher improvement in the MASI score (P = 0.000). The Dermoscopic melasma score (DMS) displayed significant change and confirmed the improvement. HFUS showed a significant decrease in the thickness of the subepidermal low-echogenic band (SLEB) and increases in dermal thickness and dermal density in both groups (P = 0.000 for all). The rate of very satisfied responses was significantly higher in the 532-nm laser group (P = 0.001). There was no significant difference in the visual analog scale pain assessment score (P = 0.248) and recurrence rate (P = 0.734) between the two groups.
CONCLUSION: 532-nm QS-Nd: YAG laser (shortwave toning) proved to be an effective and safe treatment for melasma and rejuvenation. Shortwave toning was significantly better for pigmentation clearance, while 1,064-nm laser showed better improvement in skin rejuvenation.