MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lsm.23763

Медицинская библиотека · Lasers in surgery and medicine · 2024

Comparison of 755-nm picosecond alexandrite laser versus 1064-nm Q-switched Nd:YAG laser for melasma: A randomized, split-face controlled, 2-year follow-up study.

Zhou Yanjun, Li Yong, Hamblin Michael R, Wen Xiang

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Pulsed laser treatment of melasma has shown some promising results. To compare the effectiveness and safety of 755-nm picosecond alexandrite laser (PSAL) fitted with diffractive lens array (DLA) versus 1064-nm Q-switched neodynimum:yttrium aluminum garnet laser (QSNYL) for the treatment of melasma.

METHODS

We conducted a randomized, split face controlled, 2-year follow-up study. Each face was divided into two parts, each side receiving three treatments with either PSAL or QSNYL at 1 month intervals. Modified Melasma Area Severity Index scores (mMASI), pain scores, patient satisfaction and adverse events were recorded. In vivo reflectance confocal microscopy (RCM) images were acquired.

RESULTS

Twenty subjects were enrolled and three dropped out. At 6 months, mMASI scores were significantly lower than baseline for QSNYL sides (p = 0.022), with no statistically significant difference between PSAL sides before and after treatment, PSAL sides versus QSNYL sides, or patient satisfaction scores. QSNYL treatment was associated with less pain (p = 0.014). No serious adverse events were reported. In the PSAL sides RCM showed a large number of dendritic melanocytes infiltrated in the dermis at 2 weeks and 4 weeks after treatment. Ten patients (58.82%) reported recurrence or exacerbation at 2-year follow-up with no statistically significant difference between the two lasers.

CONCLUSIONS

QSNYL demonstrated short term clinical efficacy for melasma, but did not provide any additional benefit compared to PSAL with DLA. QSNYL was associated with less pain. There was a high recurrence rate at 2-year follow-up. RCM allowed the detection of cellular changes in melasma lesions.

Для цитирования: Zhou Yanjun, Li Yong, Hamblin Michael R, Wen Xiang. Comparison of 755-nm picosecond alexandrite laser versus 1064-nm Q-switched Nd:YAG laser for melasma: A randomized, split-face controlled, 2-year follow-up study.. Lasers in surgery and medicine. 2024. DOI: 10.1002/lsm.23763.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.