MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000000898

Медицинская библиотека · Journal of cataract and refractive surgery · 2022

Mapping of corneal birefringence in thin and asymmetric keratoconus corneas with ultrahigh-resolution polarization-sensitive OCT.

Patil Rahul, Shetty Rohit, Narasimhan Raghav, Patel Yash, Khamar Pooja, Pircher Michael, Hitzenberger Christoph K, Nuijts Rudy M M A, Sinha Roy Abhijit

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate phase retardation (PR) across healthy eyes and eyes with thin corneas (<500 μm) and with asymmetric and bilateral keratoconus (KC).

SETTING

Narayana Nethralaya Eye Hospital, Bangalore, India.

DESIGN

Observational cross-sectional.

METHODS

There were 4 eye groups: healthy eyes (Group 1; n = 10 eyes), eyes with thin corneas and no clinical disease (Group 2; n = 10 eyes), eyes with asymmetric KC (Group 3; n = 5 eyes), and eyes with clinical KC (Group 4; n = 15 eyes). All eyes were imaged with polarization-sensitive optical coherence tomography (PS-OCT), MS-39, and Corvis-ST. Using PS-OCT, PR was analyzed in annular regions. The anterior (A-E) and Bowman (E-B) wavefront aberrations, epithelial Zernike indices (EZI), total corneal thickness, Corvis biomechanical index (CBI), total biomechanical index (TBI), and Belin-Ambrósio overall deviation index (BAD-D) were analyzed.

RESULTS

Only CBI, TBI, BAD-D, A-E and E-B aberrations, EZI, and total corneal thickness distributions of Groups 1 (n =10), 2 (n =10), and 3 (n =5) were similar ( P > .05) but not CCT ( P < .05). PR distributions clearly showed that the eyes in Groups 1, 2, and 3 had a normal corneal birefringence unlike Group 4 (n = 10) eyes ( P < .05). The PR map was similar to the preferred orientations of collagen fibers seen in X-ray diffraction ex vivo studies of corneal stroma.

CONCLUSIONS

PR distributions may eliminate the uncertainty associated with the stromal status of thin and asymmetric KC corneas. Group 2 and 3 eyes appeared as healthy because of normal corneal birefringence at the time of imaging, but a longitudinal follow-up of these eyes with PS-OCT may assist in early detection of onset of disease.

Для цитирования: Patil Rahul, Shetty Rohit, Narasimhan Raghav, Patel Yash, Khamar Pooja, Pircher Michael, Hitzenberger Christoph K, Nuijts Rudy M M A, Sinha Roy Abhijit. Mapping of corneal birefringence in thin and asymmetric keratoconus corneas with ultrahigh-resolution polarization-sensitive OCT.. Journal of cataract and refractive surgery. 2022. DOI: 10.1097/j.jcrs.0000000000000898.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.