MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_395_21

Медицинская библиотека · Indian journal of ophthalmology · 2022

Intraocular lens power calculation changes before and after isotonic collagen cross-linking in keratoconus patients.

Namitha V G, Kumar Dhivya Ashok

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To find the intraocular lens (IOL) power calculation changes before and after isotonic collagen cross-linking (CXL) in keratoconus patients.

METHODS

: Thirty-five eyes of 25 patients who underwent isotonic CXL were included. The cases included conventional CXL (n = 16), accelerated CXL (n = 7), contact lens-assisted CXL (CACXL) (n = 9), accelerated CACXL (n = 3). All underwent ocular biometry (IOL master), corneal topography (Orbscan II), and simulated keratometry (Orbscan II) preoperatively and 1-year post CXL. Change in best-corrected visual acuity (BCVA), axial length (AL), simulated keratometry (Sim K), anterior chamber depth (ACD), and IOL power were analyzed in the overall data and then grouped based on flattening (Group A) and no flattening (Group B) of Sim K value post CXL procedure.

RESULTS

For the overall data, there was no significant change in IOL power (P = 0.05) at the end of 1 year, BCVA showed a significant increase (P < 0.01), and Sim K reading showed a statistically significant flattening (P = 0.001); ACD and AL showed insignificant change. In intergroup comparison, there was no statistically significant change in IOL power. However, in Group A, a significant change in BCVA and Sim K values was observed. In both groups (Group A and Group B), IOL power was found to be negatively correlated with AL and Sim K values.

CONCLUSION

Isotonic CXL did not affect IOL power calculation at the end of 1 year. However, significant change in BCVA and sim K reading was noted.

Для цитирования: Namitha V G, Kumar Dhivya Ashok. Intraocular lens power calculation changes before and after isotonic collagen cross-linking in keratoconus patients.. Indian journal of ophthalmology. 2022. DOI: 10.4103/ijo.ijo_395_21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.