Correction of Ocular Aberrations with Prismatic Rigid Gas-permeable Contact Lenses in Keratoconic Eyes.

Carballo-Alvarez Jesus, Caballero-Magro Elena, Cortes-Escudero Irene, Carpena-Torres Carlos

СтатьяПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: A base-down prism was incorporated on the anterior surface of rigid gas-permeable (RGP) contact lenses to explore potential effects on the residual ocular aberrations after contact lens fitting in keratoconic eyes.

PURPOSE: This study aimed to evaluate the correction of ocular aberrations with corneal prismatic RGP contact lenses in keratoconic eyes and their impact on visual function.

METHODS

A cross-sectional and randomized study was performed. Seventeen eyes of 17 keratoconus patients (34.6 ± 11.1 years) were evaluated. Two designs (standard and prismatic) of a corneal RGP contact lens (KAKC; Conoptica, Barcelona, Spain) were fitted to the same eye of each patient in a random order: a standard RGP contact lens as control and a prismatic RGP contact lens with a base-down prism of 1.6 prism diopters. Ocular aberrations were measured for a pupil diameter of 3 mm with and without both contact lenses, whereas high-contrast distance visual acuity, low-contrast distance visual acuity, and contrast sensitivity were measured under photopic and mesopic conditions.

RESULTS

Both contact lenses improved oblique primary astigmatism, defocus, vertical coma, coma-like, and root-mean-square higher-order aberrations compared with the unaided eyes (P < .05). Furthermore, the prismatic RGP contact lenses offered lower values of vertical coma and root-mean-square higher-order aberrations than the standard RGP contact lenses (P < .05). Both designs (standard and prismatic) produced a positive vertical coma of lower magnitude than the negative vertical coma of the unaided eyes. On the other hand, the improvement achieved in all visual function variables was the same for both contact lens designs (P ≥ .05).

CONCLUSIONS

The prismatic RGP contact lenses corrected higher levels of higher-order aberrations compared with the standard RGP contact lenses. However, both contact lens designs with the same refractive power were equally efficient at improving visual function.

Для цитирования: Carballo-Alvarez Jesus, Caballero-Magro Elena, Cortes-Escudero Irene, Carpena-Torres Carlos. Correction of Ocular Aberrations with Prismatic Rigid Gas-permeable Contact Lenses in Keratoconic Eyes.. Optometry and vision science : official publication of the American Academy of Optometry. 2021. DOI: 10.1097/opx.0000000000001801.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.