Detection of Subclinical Keratoconus With a Validated Alternative Method to Corneal Densitometry.

Consejo Alejandra, Jiménez-García Marta, Issarti Ikram, Rozema Jos J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To enhance the current standards of subclinical keratoconus screening based on the statistical modeling of the pixel intensity distribution of Scheimpflug images.

METHODS

Scheimpflug corneal tomographies corresponding to 25 corneal meridians of 60 participants were retrospectively collected and divided into three groups: controls (20 eyes), subclinical keratoconus (20 eyes), and clinical keratoconus (20 eyes). Only right eyes were selected. After corneal segmentation, pixel intensities of the stromal tissue were statistically modeled using a Weibull probability density function from which parameter α (pixel brightness) was derived. Further, data were transformed to polar coordinates, smoothed, and interpolated to build a map of the corneal α parameter. The discriminative power of the method was analyzed using receiver operating characteristic curves.

RESULTS

The proposed platform-independent method achieved a higher performance in discriminating subclinical keratoconus from control eyes (90.0% sensitivity, 95.0% specificity, 0.97 area under the curve [AUC]) than the standard method (Belin-Ambrósio enhanced ectasia display), which uses only corneal morphometry (85.0% sensitivity, 85.0% specificity, 0.80 AUC).

CONCLUSIONS

Analysis of light backscatter at the cornea successfully discriminates subclinical keratoconus from control eyes, upgrading the results previously reported in the literature.

TRANSLATIONAL RELEVANCE: The proposed methodology has the potential to support clinicians in the detection of keratoconus before showing clinical signs.

Для цитирования: Consejo Alejandra, Jiménez-García Marta, Issarti Ikram, Rozema Jos J. Detection of Subclinical Keratoconus With a Validated Alternative Method to Corneal Densitometry.. Translational vision science & technology. 2021. DOI: 10.1167/tvst.10.9.32.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.