Effect of intracorneal ring segment implantation on high order aberrations comparing patients with eccentric versus central keratoconus.

Anders Philipp, Anders Lisa-Marie, Elalfy Mohamed, Hamada Samer, Seitz Berthold, Gatzioufas Zisis

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess potential differences between central and eccentric cones in the aberrometric corneal profile and in visual and keratometric outcomes 6 months after intracorneal ring segment (ICRS) implantation for keratoconus.

METHODS

This study compared two groups consisting of 12 patients each, with central or eccentric keratoconus who were treated with femtosecond laser-assisted Keraring implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, keratometric readings and higher order aberrations (HOAs) including high order aberrations root mean square (HOARMS), coma, spherical aberration and trefoil were measured preoperatively and 6 months after ICRS implantation.

RESULTS

Trefoil and spherical aberration were significantly reduced after ICRS implantation compared to preoperative values in eccentric keratoconus (Trefoil, p = 0.0049; Spherical aberration, p < 0.0001). In central keratoconus spherical aberration was reduced not significantly after ICRS implantation compared to preoperative values (p = 0.087). Coma showed a significant reduction in central (p = 0.0001) and in eccentric keratoconus (p = 0.0001). The reduction of spherical aberration in central keratoconus was significantly positively correlated to improvement in UDVA (Pearson's correlation coefficient, r = -0.66; p = 0.02). In eccentric keratoconus there was a significant positive correlation between reduction of trefoil and improvement in UDVA (Spearmans R, r = -0.69; p = 0.01).

CONCLUSION

Patients both with central and eccentric keratoconus benefit from ICRS implantation. Specifically, our data provide a slightly higher gain in visual performance for eccentric cones 6 month after ICRS implantation, which is accentuated by a greater reduction in spherical aberration and trefoil. Improvements in UDVA are positively correlated with reductions in HOAs.

Для цитирования: Anders Philipp, Anders Lisa-Marie, Elalfy Mohamed, Hamada Samer, Seitz Berthold, Gatzioufas Zisis. Effect of intracorneal ring segment implantation on high order aberrations comparing patients with eccentric versus central keratoconus.. European journal of ophthalmology. 2021. DOI: 10.1177/11206721211041022.