MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000000740

Медицинская библиотека · Journal of cataract and refractive surgery · 2022

Correlation of the Corvis Biomechanical Factor with tomographic parameters in keratoconus.

Flockerzi Elias, Vinciguerra Riccardo, Belin Michael Wellington, Vinciguerra Paolo, Ambrósio Renato, Seitz Berthold

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the relationship between corneal biomechanics and keratoconus (KC) severity as described by tomographic parameters.

SETTING

University-based German ophthalmology department.

DESIGN

Retrospective cross-sectional study.

METHODS

A total of 448 KC corneas of the Homburg Keratoconus Center and 112 healthy corneas (448+112 patients) were examined by Pentacam high-resolution and Corneal Visualization Scheimpflug Technology (Pentacam HR and Corvis ST). The KC population included a wide spectrum of disease severity based on Belin's ABCD classification. Linear regression analysis was performed between the linear term of the Corvis Biomechanical Index (CBI) (CBI beta) and the tomographic values anterior radius of curvature (ARC), posterior radius of curvature (PRC), and thinnest corneal thickness (TCT). A linear transformation of the CBI beta was performed to provide an intuitive scaling, which was referred to as the Corvis Biomechanical Factor (CBiF = -0.24294226 × CBI beta + 6.02). This scaling adjusted the CBI beta to the same scale as posterior corneal curvature (PRC).

RESULTS

There was a high correlation of the CBI beta and its modification, the CBiF, with TCT (Pearson, r = -0.775), ARC (r = -0.835), and PRC (r = -0.839) in the KC population (P < .001). In the control corneas, the correlation between the CBI beta and ARC was weak (r = -0.216, P = .022), not significant (PRC, r = -0.146, P = .125), or moderate (TCT, r = -0.628, P < .001).

CONCLUSIONS

The linear term of the CBI was highly associated with KC severity as defined by corneal tomography. The CBiF represents a new scale based on biomechanical characteristics in KC, which could serve as a basis for a biomechanical KC classification in the future.

Для цитирования: Flockerzi Elias, Vinciguerra Riccardo, Belin Michael Wellington, Vinciguerra Paolo, Ambrósio Renato, Seitz Berthold. Correlation of the Corvis Biomechanical Factor with tomographic parameters in keratoconus.. Journal of cataract and refractive surgery. 2022. DOI: 10.1097/j.jcrs.0000000000000740.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.