OBJECTIVES

To assess the quality-of-life improvement after scleral lens fitting in patients with keratoconus.

METHODS

We conducted a prospective observational study of all consecutive patients with keratoconus starting scleral lens fitting in 2019, from January 2 to December 27, at the Dijon University Hospital, France. Quality of life was assessed before and after wearing scleral lenses for 3 months through the National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ 25) questionnaire. We investigated factors potentially influencing quality of life: final visual acuity, keratoconus stage, and maximum keratometry reading.

RESULTS

In total, 41 eyes of 24 patients were successfully fitted with scleral lenses, 92.9% were 18 mm in diameter and 7.1% were 17 mm. The visual acuity improved by -0.4±0.3 logarithm of the minimum angle of resolution (P<0.001) after scleral lens fitting. Visual gain increased with keratometry and keratoconus severity (P<0.001; P<0.01). The NEI-VFQ 25 score increased by 19.5±19.1 points on average (P<0.001). No association was found between the factors under study and improvement in quality of life.

CONCLUSION

Our study confirms the functional improvement in patients with keratoconus fitted with scleral lenses, especially in patients with more advanced disease. Moreover, it suggests a major role of these lenses in improving quality of life, independently of the severity of the disease and the visual gain.

Для цитирования: Baudin Florian, Chemaly Alicia, Arnould Louis, Barrénéchea Elsa, Lestable Lolita, Bron Alain M, Creuzot-Garcher Catherine. Quality-of-Life Improvement After Scleral Lens Fitting in Patients With Keratoconus.. Eye & contact lens. 2021. DOI: 10.1097/icl.0000000000000821.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.