Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty.

van der Veen Hugo C, Reininga Inge Hf, Zijlstra Wierd P, Boomsma Martijn F, Bulstra Sjoerd K, van Raay Jos Jam

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Metal-on-metal total hip arthroplasty (MoM THA) is associated with the formation of pseudotumours. Studies mainly concern pseudotumour formation in large head MoM THA. We performed a long-term follow-up study, comparing pseudotumour incidence in small head metal-on-metal (SHMoM) THA with conventional metal-on-polyethylene (MoP) THA. Predisposing factors to pseudotumour formation were assessed.

METHODS

From a previous randomised controlled trial comparing SHMoM (28 mm) cemented THA with conventional MoP cemented THA, patients were screened using a standardised CT protocol for the presence of pseudotumours. Serum cobalt levels and functional outcome were assessed.

RESULTS

56 patients (33 MoP and 23 MoM) were recruited after mean follow-up of 13.4 years (SD 0.5). The incidence of pseudotumours was 1 (5%) in the SHMoM THA cohort and 3 (9%) in the MoP THA cohort. Prosthesis survival was 96% for both SHMoM and MoP THAs. Serum cobalt levels did not exceed acceptable clinical values (<5 µg/L) whereas no differences in cobalt levels were detected at follow-up between both groups. Oxford and Harris Hip Scores were good and did not differ between SHMoM and MoP THA.

CONCLUSIONS

This long-term follow-up study shows a low incidence of pseudotumour formation and good functional outcome in cemented head-taper matched SHMoM and MoP THA.

Для цитирования: van der Veen Hugo C, Reininga Inge Hf, Zijlstra Wierd P, Boomsma Martijn F, Bulstra Sjoerd K, van Raay Jos Jam. Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2019. DOI: 10.1177/1120700019832877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.