MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2019.01.013

Медицинская библиотека · Journal of cardiology · 2019

Self-expandable transcatheter aortic valve replacement is associated with frequent periprocedural stroke detected by diffusion-weighted magnetic resonance imaging.

Kajio Keiko, Mizutani Kazuki, Hara Masahiko, Nakao Mana, Okai Tsukasa, Ito Asahiro, Takahashi Yosuke, Iwata Shinichi, Shimono Taro, Izumiya Yasuhiro, Murakami Takashi, Shibata Toshihiko, Yoshiyama Minoru

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Little evidence is available regarding the risk of peri-procedural stroke detected by diffusion-weighted magnetic resonance imaging (DW-MRI) after transcatheter aortic valve replacement (TAVR). Our purpose was to evaluate stroke risk after TAVR using DW-MRI by enrolling consecutive patients who underwent transfemoral TAVR and post-procedural DW-MRI.

METHODS

We prospectively enrolled 113 consecutive patients who underwent transfemoral TAVR and post-procedural DW-MRI. We used balloon-expandable valves as first-line therapy and selected self-expandable valves only for patients with narrow sinotubular junctions or annuli. We set the primary endpoint as the number of high intensity areas (HIA) detected by DW-MRI regardless of the size of the area. To evaluate the risks of the primary endpoint, we employed a multivariable linear regression model, setting the primary endpoint as an objective variable and patient and clinical backgrounds as explanatory variables.

RESULTS

Median patient age was 84 years, and 36.3% were men. Ninety-three patients underwent balloon-expandable TAVR and 20 underwent self-expandable TAVR. Symptomatic stroke occurred in 6 (5.3%) whereas asymptomatic stroke occurred in 59 (52.2%) patients. The incidence of symptomatic and total stroke was higher in patients who underwent self-expandable TAVR than those who underwent balloon-expandable TAVR (30.0% vs. 0.0%, p<0.001 and 90.0% vs. 50.5%, p=0.001, respectively). A multivariable linear regression model demonstrated an increased primary endpoint when self-expandable TAVR was performed (p<0.001). The other covariates had no significant relationship to the primary endpoint. Akaike information criterion-based stepwise statistical model selection revealed that valve type was the only explanatory variable for the best predictive model.

CONCLUSIONS

Self-expandable valves were associated with increased numbers of HIA on DW-MRI after TAVR in patients with severe aortic stenosis.

Для цитирования: Kajio Keiko, Mizutani Kazuki, Hara Masahiko, Nakao Mana, Okai Tsukasa, Ito Asahiro, Takahashi Yosuke, Iwata Shinichi, Shimono Taro, Izumiya Yasuhiro, Murakami Takashi, Shibata Toshihiko, Yoshiyama Minoru. Self-expandable transcatheter aortic valve replacement is associated with frequent periprocedural stroke detected by diffusion-weighted magnetic resonance imaging.. Journal of cardiology. 2019. DOI: 10.1016/j.jjcc.2019.01.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.