Journal of vascular and interventional radiology : JVIR · 2016
Prospective Evaluation of Passive Expansion of Partially Dilated Transjugular Intrahepatic Portosystemic Shunt Stent Grafts-A Three-Dimensional Sonography Study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pieper Claus Christian, Jansen Christian, Meyer Carsten, Nadal Jennifer, Lehmann Jennifer, Schild Hans Heinz, Trebicka Jonel, Thomas Daniel
Аннотация
PURPOSE: To prospectively investigate early expansion kinetics of underdilated self-expanding stent grafts used for transjugular intrahepatic portosystemic shunt (TIPS) creation.
MATERIALS AND METHODS: Twenty patients (7 female; mean age 66 y; range, 31-80 y) with liver cirrhosis undergoing TIPS creation for variceal bleeding (n = 5), refractory ascites (n = 14), or both (n = 1) with underdilation of 10-mm stent grafts received two-dimensional (2-D) and three-dimensional (3-D) ultrasound (US) examinations immediately after TIPS creation and 1 and 6 weeks later. Orthogonal views of the TIPS within the parenchymal tract were reconstructed from 3-D volume data sets acquired in longitudinal orientation of the stent. 2-D images and reconstructed 3-D images were used for blinded diameter measurements. Measurement technique was validated with intrainterventional plain radiographs with a sizing catheter as the gold standard. Diameter changes over time and interrelations with patient characteristics (null hypothesis: no expansion, no interrelation) were analyzed using a general linear model for repeated measures.
RESULTS: After dilation to 8-mm diameter, 2-D and 3-D measurements showed stent recoil (mean diameter 7.7 mm ± 0.21 and 7.6 mm ± 0.17, respectively). Diameter increased significantly from initial measurements to measurements at 1 and 6 weeks (2-D, 8.8 mm ± 0.24 and 9.4 mm ± 0.15, both P < .001; 3-D, 8.7 mm ± 0.27 and 9.4 mm ± 0.11, both P < .001). Validation measurements showed no significant differences between 2-D or 3-D US and gold standard. There were no statistically significant associations between stent expansion and clinical parameters (sex, P = .78; age, P = .82; etiology/grade of cirrhosis, P = .99; indication for TIPS, P = .78, liver stiffness, P = .70).
CONCLUSIONS: Underdilated self-expanding stent grafts used for TIPS creation significantly expand within first 6 weeks after intervention. These changes can be noninvasively monitored using 3-D US.
MATERIALS AND METHODS: Twenty patients (7 female; mean age 66 y; range, 31-80 y) with liver cirrhosis undergoing TIPS creation for variceal bleeding (n = 5), refractory ascites (n = 14), or both (n = 1) with underdilation of 10-mm stent grafts received two-dimensional (2-D) and three-dimensional (3-D) ultrasound (US) examinations immediately after TIPS creation and 1 and 6 weeks later. Orthogonal views of the TIPS within the parenchymal tract were reconstructed from 3-D volume data sets acquired in longitudinal orientation of the stent. 2-D images and reconstructed 3-D images were used for blinded diameter measurements. Measurement technique was validated with intrainterventional plain radiographs with a sizing catheter as the gold standard. Diameter changes over time and interrelations with patient characteristics (null hypothesis: no expansion, no interrelation) were analyzed using a general linear model for repeated measures.
RESULTS: After dilation to 8-mm diameter, 2-D and 3-D measurements showed stent recoil (mean diameter 7.7 mm ± 0.21 and 7.6 mm ± 0.17, respectively). Diameter increased significantly from initial measurements to measurements at 1 and 6 weeks (2-D, 8.8 mm ± 0.24 and 9.4 mm ± 0.15, both P < .001; 3-D, 8.7 mm ± 0.27 and 9.4 mm ± 0.11, both P < .001). Validation measurements showed no significant differences between 2-D or 3-D US and gold standard. There were no statistically significant associations between stent expansion and clinical parameters (sex, P = .78; age, P = .82; etiology/grade of cirrhosis, P = .99; indication for TIPS, P = .78, liver stiffness, P = .70).
CONCLUSIONS: Underdilated self-expanding stent grafts used for TIPS creation significantly expand within first 6 weeks after intervention. These changes can be noninvasively monitored using 3-D US.
Предметные рубрики MeSH
AdultAgedAged, 80 and overAscitesBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationEsophageal and Gastric VaricesFemaleGastrointestinal HemorrhageHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalKineticsLiver CirrhosisMaleMiddle AgedPortasystemic Shunt, Transjugular IntrahepaticPredictive Value of TestsProspective StudiesProsthesis DesignReproducibility of ResultsStentsTreatment OutcomeUltrasonography